WIRING DIAGRAMS
BL
LPS
YL/PK
BL
L1
L2
C
BC
T1
T2
RD
BK
BK
EM
SEE NOTE 4
L1
C
T1
BC
R
HVDR
CHS
R
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
BK
BR
RD
RD
GR
G
EBTDR
NO
R
K1
XFMR-R
GR
RD
XFMR-C
COM
K1
C
PU
NC
SPEED
BL
M1
M2
UP
BL
BR
DC
YL/PK
CCR
PU
CNT
0
OR
0
LVDR
BK
0-RV
GR
C-RV
W
Y
HVDR
BK
Y
PS2
RCCF
BL
L3
BR
RD
BK
RD
T3
OR
RD
CHR
RD
RD
BK
BL
BK
DFT
BK
CH
GR
RVC
460-575/3/60
C
T2
T2
T1
T1
COMP
C
T3
T3
C
DF1
DF2
RCCF
HVDR
F
CM
CHR
3
1
BC
T2
T3
EM
BC
460V - 575V
3
1
TR
24V
EBTDR
R
C
G
EBTDR
EBTDR
CHR
HPS
P
P
9 8 7
4
L
L
6
F
F
5
3
1
1
6
W1
W1
Y1
Y1
G
G
S1
S1
S2
S2
O
O
R
R
W2
W2
Y2
THERMOSTAT ++
DSH036* (4B/7B)/DSH048* (4B/7B)/DSH060* (4B/7B)
RD
BK
1
3
BL
460
C
575
BR
TR
24V
PK
BL
RD
BR
RD
BR
RD
WH
WH
PU
PU
3
6
9
C
F
2
5
8
RD
BR
1
4
7
1
3
PLF 1
BL
2
CMR
PU
BL/PK
PU
BK
BL/PK
BR
HPS
CM
RD
BL
COMPONENT LEGEND
BC
BLOWER CONTACTOR
L2
L3
C
CONTACTOR
CCR
COMPRESSOR CONTACTOR RELAY
CH
CRANKCASE HEATER
CHS
CRANKCASE HEATER SWITCH
CHR
CRANKCASE HEATER RELAY
CM
CONDENSER MOTOR
CMR
CONDENSER MOTOR RELAY
COMP
COMPRESSOR
DC
DEFROST CONTROL
DFT
DEFROST THERMOSTAT
ECON
ECONOMIZER
EBTD
ELECTRONIC BLOWER TIME DELAY
EMR
EVAPORATOR MOTOR RELAY
EM
EVAPORATOR MOTOR
GND
EQUPIMENT GROUND
HPS
HIGH PRESSURE SWITCH
HVDR
HIGH VOLTAGE DEFROST RELAY
LPS
LOW PRESSURE SWITCH
LVDR
LOW VOLTAGE DEFROST RELAY
PLF
FEMALE PLUG / CONNECTOR
RVC
REVERSING VAVLE COIL
RCCF
RUN CAPACITOR FOR
CONDENSER FAN
TB1
TERMINAL BLOCK (24V SIGNAL)
TR
TRANSFORMER
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND
TYPE INSULATION AS ORIGINAL (AT LEAST 105 C)
USE COPPER CONDUCTOR ONLY.
2. USE COPPER CONDUCTORS ONLY
++
USE N.E.C. CLASS 2 WIRE
3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR
CMR
COMPARTMENT. REMOVE MALE PLUG AND ATTACH
FEMALE PLUG TO THE ECONOMIZER ACCESSORY.
4. CRANKCASE HEATER, CRANKCASE HEATER RELAY,
AND CRANKCASE HEATER SWITCH FACTORY
EQUIPPED WHEN REQUIRED.
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
JUNCTION
BC
TERMINAL
INTERNAL TO
INTEGRATED
CONTROL
C
PLUG
CONNECTION
PLF2
SWITCH (PRESS.)
4
5
OVERCURRENT
2
1
PROT. DEVICE
C
C
SEE NOTE 3
39
THREE PHASE 460/575V/3/60HZ BELT DRIVE
OR
BK
RD
BK
BL
RD
BL
YL
T3
L3
RD
T2
L2
RD
C
BK
L1
T1
BK
SEE
NOTE 2
PU
GND
BL
OR
RD
GR
PLF 2
3
6
6
9
3
2
2
8
PU
5
5
4
4
7
1
1
YL
YL
BL
YL
PU
RD
RD
GR
GR
WH
WH
BR
OR
TB1
OR
BL
BL
RD
BR
BR
PK
RD
CHS
RD
BK
SEE NOTE 4
YL
RD
T3
T1
T2
REPLACE JUMPER WITH
SMOKE / FIRE DETECTOR
COMP
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTIONAL
HIGH VOLTAGE
OPTIONAL
LOW VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PK PINK
PU PURPLE
RD RED
WH WHITE
YL YELLOW
BL/PK BLUE WITH PINK STRIP
YL/PK YELLOW WITH PINK STRIP
THERMOSTAT
FIELD WIRING
NO ECONOMIZER
W
G
R
Y1
Y2
C
O
TB1
WITH ECONOMIZER OPTION
W
G
R
Y1
YL
Y2
C
EQUIPMENT
O
GROUND
TB1
FIELD GROUND
2 STAGE COOLING
W
FIELD SPLICE
G
SWITCH (TEMP)
R
IGNITER
Y1
Y2
C
O
TB1
4
6
0
L3
-
5
L2
7
5
L1
/
3
/
6
0
T
Y1
H
Y2
E
R
R
G
M
W1
O
W2
S
O
T
C
A
S2
T
S1
BL
WH
W
GR
G
RD
R
YL
Y
BL
C
OR
O
STAT
WH
W
GR
G
RD
R
Y
BL
C
OR
O
STAT
WH
W
GR
G
RD
R
YL
Y1
PK
Y2
BL
C
OR
O
STAT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsh seriesDsc036Dsc048Dsc060Dsh036Dsh048 ... Show all