MEASUREMENT WITH INTERVAL MODE FOR HRT

The heat run timer must be started the moment that
the heat source is switched off from the test object.
Press the "Timer" Button on the main screen to start
the timer.
The timer starts running.
The timer can be halted, at any time, by pressing
the button a second time.
Note: The test current is NOT switched on at this
time.
After starting the timer, disconnect the power cables
or heat source of the test object and connect the
measurement cables of the instrument.
Measurement results should be obtained as quickly
as possible.
After the measuring cables are attached to the
transformer windings, press "START" to start the
measurement.
The current is applied and the system charges the
transformer winding(s) to be measured.
Version 3.03
WR14 / WR50-12/13 Winding Resistance Meter Instruction Manual