4Receiving inspection
Upon receiving the pump, it should
be
inspected
for
shortages. If damage has occurred,
file a claim immediately with the
company that delivered the pump. If
the manual is removed from the
packaging, do not lose or misplace.
4Storage
Any product that is stored for a
period longer than six (6) months
from the date of purchase should be
bench tested prior to installation. A
bench test consists of, checking the
impeller to assure it is free turning
and a run test to assure the motor
(and switch if provided) operate
properly. Do not pump out of liquid.
4Location
Locate the unit as close as possible to
barmesa.com
the liquid being pumped in order to
reduce friction losses in the suction
pipe. Suction and discharge piping
should be perfectly aligned with the
pump
flanges
and
independently using pipe hangers or
floor mounted supports.
**Consult pipe friction table and
accessories in order to determine your
piping dimensions.
4Suction
Recommended to use robust and
self-supported piping and inspect for
any leakage.
For a successful installation you need
to rely on the friction loss calculation
in the suction part taking into
consideration the acceptable limits.
The minimum suction pipe to be
used can be determine by comparing
the NPSH available in the suction
part versus the NPSH require by the
impeller,
as
illustrated
performance curve.
Generally, we recommend to use ½"
to 1" bigger diameter piping to what
the pump suction diameter is.
4Typical installation diagrams for BVL's
damage
or
RECOMMENDED FIELD
supported
PIPING ARRANGEMENT
RECOMMENDED FIELD
PIPING ARRANGEMENT
in
the
SUCTION
HANGER SUPPORTED
PIPE MOUNTED
HANGERS SUPPORTED THE
WEIGHT OF THE FILLED PIPING,
PUMPS AND FITTINGS
SYSTEM
INLET
PRESSURE GAUGE
SUCTION
GUIDE
DRAIN
CONNECTION
PIPE MOUNTED SUPPORTED AT CEILING
HANGERS SUPPORTED THE
WEIGHT OF THE FILLED PIPING,
PUMPS AND FITTINGS
SYSTEM
INLET
PRESSURE GAUGE
SUCTION
GUIDE
DRAIN
CONNECTION
DISCHARGE ELBOW FOR MINIMUM FOOTPRINT
Receiving & Installation
DISCHARGE
FLUSH LINE
FLO-TREX VALVE
DRAIN
FLUSH LINE
FLO-TREX VALVE
ELBOW 90°
DRAIN