IMPORTANT! - Barmesa Pumps is not systems, that are required to reduce installations where there is responsible for losses, injury or the potencial for property damage.
Recommendations and Warnings 4Receiving inspection 4 Installation 4Liquid Level Controls Upon receiving the pump, it should These pumps are recommended for The level control(s) should be inspected damage use in a sump, basin or lift station. mounted on the discharge piping, a shortages.
Installation & Service These situations ma y induce a false IMPORTANT! - The overload will then signal in the moisture etecting automatically reset and start the circuit. If none of the above test pump up after the motor cools to a prove conclusive, the pump(s) should safe temperature.
Page 7
Service a) Inspect motor chamber for oil If oil is found to be clean and Use soap solution around the sealed Ÿ level and contamination. uncontaminated (measuring areas above the oil level and nspect b) Inspect impeller and body for above 15 V breakdown), re ill joints for "air bubbles".
Page 8
Service 4Disassembly Apply adhesive compound to the Motor and Bearings - Remove Impeller and Volute - Disconnect shaft and press bearing (1 ) onto volute, impeller, seal plate and seal as power. Remove hex nuts ( ) and previously stated and drain oil from shaft, position squarely onto the vertically lift motor housing and seal shaft applying force to the inner race...
Page 9
Service Thread cap screws (25) into bearing housing (15) and tighten. Refill chamber with oil. Conduit Box Assembly - Check power (38) and control cables (39) for crackes or damage and replace complete conduit box (4) if required. (See Figure 4) Bring motor wires through opening in top of motor housing (3), check sleeving and replace if damaged.
Page 10
Service Wear Ring Apply retaining compound to the bore of volute (37) and press wear ring (33) into bore until seated. Impeller and Volute - Install impeller (32) by appling a thin film of oil to motor shaft and slide impeller straight onto shaft, keeping keyways lined up.
Page 11
Repair Parts Figure 6 barmesapumps.com VOLUTE FOR 6BSE-HLDS For Repair Part Please supply: Model Number and Serial as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
Page 12
Parts List 46BSE-LDS barmesapumps.com 30400423 For Repair Part Please supply: Model Number and Serial as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
Page 13
Parts List 46BSE-HLDS barmesapumps.com 30400423 For Repair Part Please supply: Model Number and Serial as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
13. Piping attachments to building structure too loose or rigid NOTE: Barmesa Pumps assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other than at Barmesa Pumps or its authorized service centers, automatically voids warranty.