LP-Gas Supply System
If the information is not followed exactly, a fire resulting in death or serious injury could occur.
The LP gas supply cylinder to be used must be constructed and marked in accordance with the specifications for
LP-Gas cylinder of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA –
B339, Cylinders, Spheres and Tubes for Transportation of Dangerous Goods and Commission .
The LP gas tank must have a shutoff valve terminating in an LP valve outlet that is compatible with a Type 1. LP
gas supply cylinder must have a shut off valve terminating in a valve outlet specified for connection type QCC1 in
the standard for compressed gas cylinder valve outlet and inlet connection ANSI/CGA-V-1 as applicable. LP gas
supply cylinder must be fitted with an Overfill Protection Device (O.P.D.) The LP gas tank must also have a safety
relief device that has a direct connection with the vapor space of the tank. This safety feature prevents the tank
from being overfilled, which can cause malfunction of the LP gas tank, regulator and/or grill.
304.8 mm
/ 11.9 in.
This is a liquid propane configured grill.
natural gas.
This outdoor cooking gas appliance is equipped with a high-capacity
hose/regulator assembly for connection to a standard 9.07 kg (20 lb) Liquid
propane cylinder.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity
of this or any other appliance.
Storage of an outdoor cooking gas appliance indoors is permissible only if the
cylinder is disconnected and removed from the outdoor cooking gas appliance.
When your gas grill is not in use, the gas must be turned off at LP gas tank.
Any brand of 9.07 kg (20 lb) LP gas fuel tank is acceptable for use with the grill,
provided that it is compatible with the grill's retention means.
The 9.07 kg (20 lb) LP gas fuel tank must be mounted and secured.
Proper Placement and Clearance of Grill
Never use your gas grill in a garage, porch, shed, breezeway or any other enclosed area. Your gas grill is to be
used outdoors only.
Do not install this unit into combustible enclosures. Minimum clearance from sides and back of unit to
combustible construction, 91 cm / 36 in. from sides and 91 cm / 36 in. from back.
Do not use this appliance under overhead combustible surfaces.
LP gas tank must be stored outdoors in a well-ventilated area and out of reach of children. Disconnected LP gas
tanks must not be stored in a building, garage or any other enclosed area.
Do not obstruct the flow of ventilation air around the gas grill housing. Only use the regulator and the hose
assembly supplied with your gas grill. Replacement regulators and hose assemblies must be those specified in
this manual.
The regulator and hose assembly must be inspected before each use of the grill. If there is excessive abrasion or
wear or if the hose is cut, it must be replaced prior to the grill being put into operation. The replacement hose
assembly shall be that specified by the manufacturer.
Pressure regulator and hose assembly supplied with the outdoor cooking gas appliance must be used. Never
substitute other types of regulator. Contact customer service for manufacturer specified replacement parts.
This outdoor cooking gas appliance is equipped with a pressure regulator comply with the standard for Pressure
Regulating Valves for LP Gas ANSI/ UL 144.
Do not use briquettes of any kind in the grill.
The grill is designed for optimum performance without the use of briquettes. Do not place briquettes on the
radiant as this will block off the area for the grill burners to vent. Adding briquettes can damage ignition
components and knobs, and void the warranty.
Keep the back and side cart free and clear from debris. Keep any electrical supply cord and the fuel supply hose
away from any heated surfaces.
CAUTION: TO ENSURE CONTINUED PROTECTION AGAINST RISK OF ELECTRIC SHOCK, CONNECT TO PROPERLY
GROUNDED OUTLETS ONLY, TO REDUCE THE RISK OF ELECTRIC SHOCK, KEEP EXTENSION CORD CONNECTION DRY
AND OFF THE GROUND.
A 9.07 kg (20 lb) tank of approximately 304.8 mm / 11.9 in diameter by 469.9
mm / 18.49 in high is the maximum size LP gas tank to use.
The tank supply system must be arranged for vapor withdrawal.
The LP gas tank used must have a collar to protect the tank valve.
Place dust cap on cylinder valve outlet whenever the cylinder is not in use.
Only install the type of dust cap on the cylinder valve outlet that is provided
with the cylinder valve. Other types of cap or plugs may result in leakage of
propane.
Never connect an unregulated LP gas tank to your gas grill.
Do not store a spare LP gas cylinder under or near this appliance.
Never fill the cylinder beyond 80 percent full.
Always keep LP gas tanks in an upright position.
Have your LP gas tank filled by a reputable propane gas dealer and visually
inspected and re-qualified at each filling.
Do not attempt to reconfigure grill for use with