Gas Hook-Up - Nexgrill NEEVO 720-1055 Owner's Manual

Digital smart grill in black with air oven
Table of Contents

Advertisement

Available languages

Available languages

GAS HOOK-UP

LP TANK REQUIREMENT
A dented or rusty LP tank may be hazardous and should be checked by your LP supplier. Never use a cylinder with
a damaged valve. The LP gas cylinder must be constructed and marked in accordance with the specifications for LP
gas cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339,
Cylinders, Spheres and Tubes for Transportation of Dangerous Goods; and Commission, as applicable. Overfilling
prevention device (OPD) shall be provided on cylinder & QCC1 connection on the cylinder valve, ANSI/CGA-V-1. The
cylinder supply system must be arranged for vapor withdrawal. The cylinder must include a collar to protect the
cylinder valve. The cylinder must be provided with a shut off valve terminal in an LP gas supply cylinder valve outlet
specified, as applicable, for connection type QCC1 in the standard for compressed gas cylinder valve outlet and
inlet connection ANSI/CGA-V-1. Manifold pressure: 11" water column (W.C.).
LP GAS HOOK-UP
Ensure that the black plastic grommets on the LP cylinder valve are in place and that the hose does not come
into contact with the grease tray or the grill head.
CONNECTION
Your stainless steel grill is equipped with gas supply orifices for use only with liquid propane gas. It is also equipped
with a high capacity hose/regulator assembly for connection to a standard 9.07 kg (20 lb). LP cylinder 469.9 mm / 18-
1/4 in. high, 304.8 mm / 12-1/4 in. diameter).
TO CONNECT THE LP GAS SUPPLY CYLINDER:
1. Make sure tank valve is in its full off position (turn clockwise to stop).
2. Check tank valve to assure it has proper external male
threads (type 1 connection per ANSIZ21.81).
3. Make sure all burner valves are closed and the controller is off.
4. Inspect valve connections, port, and regulator assembly. Look for any
damage or debris. Remove any debris. Inspect hose for damage. Never
attempt to use damaged or obstructed equipment. See your local LP gas
dealer for repair.
5. When connecting regulator assembly to the valve, hand tighten the quick
coupling nut clockwise to a complete stop. Do not use a wrench to tighten. Use
of a wrench may damage the quick coupling nut and result in a hazardous condition.
6. Open the tank valve fully (counterclockwise). Apply the soap solution with a clean brush to all gas connections.
See below. If growing bubbles appear in the solution the connections are not properly sealed. Check each fitting
and tighten or repair as necessary.
7. If you have a gas connection leak you cannot repair, turn gas OFF at supply tank, disconnect fuel line from your
grill and call 1-800-913-8999 in USA and 1-800-648-5864 in Canada or your gas supplier for repair assistance.
8. Also apply soapy solution to the tank seams. See below. If growing bubbles appear, shut tank OFF and do not use
or move it! Contact an LP gas supplier or your fire department for assistance.
TO DISCONNECT LP GAS CYLINDER:
1. Turn the burner valves off.
2. Turn the tank valve off fully (turn clockwise to stop).
3. Detach the regulator assembly from the tank valve by
turning the quick coupling nut counterclockwise.
PROPANE CYLINDER CAUTIONS:
a)
Do not store a spare LP-gas cylinder under or near this appliance.
b)
NEVER fill the cylinder beyond 80 percent full.
c)
If the information in "a" and "b" is not followed exactly, a fire or explosion causing death or serious
injury may occur.
30

Advertisement

Table of Contents
loading

Table of Contents

Save PDF