ALWAYS CHECK FOR LEAKS AFTER EVERY LP TANK CHANGE.
GENERAL
Although all gas connections on the grill are leak tested at the factory prior to shipment, a complete gas leak test
check must be performed at the installation site due to possible mishandling in shipment, or excessive pressure
unknowingly being applied to the unit. Periodically check the whole system for leaks following the procedures listed
below. If the smell of gas is detected at anytime, you should immediately turn off grill and check the entire system for
leaks.
Before testing, make sure that all packing material is removed from the grill including tie-down straps.
DO NOT SMOKE WHILE LEAK TESTING. NEVER PERFORM LEAK TEST WITH AN OPEN FLAME.
Make a soap solution of one part liquid detergent and one part water. You will need a spray bottle, brush, or rag to
apply the solution to the fittings. For the initial leak test, make sure the LP cylinder is 80% full.
Only those parts recommended by the manufacturer should be used on the grill. Substitution will void the warranty. Do
not use the grill until all connections have been checked and do not leak.
GAS FLOW CHECK
Each grill burner is tested and adjusted at the factory prior to shipment; however, variations in the local gas supply may
make it necessary to adjust the burners. The flames of the burners should be visually checked. Flames should be blue
and stable with no yellow tips, excessive noise or lifting. If any of these conditions exist, check to see if the air shutter
or burner ports are blocked by dirt, debris, spider webs, etc. If you have any questions regarding flame stability, please
call customer service.
✓ Minimum clearance from sides and back of unit to
combustible construction, 91 cm / 36 in. from sides and
91 cm / 36 in. from back
✓ All internal packaging removed
✓ Burners are tight and sitting properly on orifices
Check all gas supply fittings for leaks before each use. It is handy to keep a spray
bottle of soapy water near the shut-off valve of the gas supply line. Spray all the
fittings. Bubbles indicate leaks.
TO TEST:
1.
Make sure the grill is powered off, then open the cylinder valve
on the LP tank.
2.
Check all connections from the LP gas regulator and supply valve
up to and including the connection to the manifold pipe assembly
(the pipe that goes to the burners). Soap bubbles will appear
where a leak is present.
3.
If a leak is present, immediately turn off the gas supply and
tighten the leaky fittings.
4.
Turn the gas back on and recheck.
5.
Should the gas continue to leak from any of the fittings, turn off
the gas supply and contact customer service at 1-800-913-8999 in
USA and 1-800-648-5864 in Canada. Languages spoken: English,
French, Spanish 8 a.m.-5 p.m., PST. Monday-Friday.
INSTALLER FINAL CHECK LIST
✓ Pressure regulator connected and set. Gas connections
to grill using hose & regulator assembly provided (pre-
set for 11 in. water column)
✓ Unit tested and free of leaks
✓ Do not store a spare LP-gas cylinder under or near this
appliance