Table 7-2 Parameters
Type
Enable
Default Min
Setup
Always
Setup
X250
Setup
Always
Setup
Flooded
Setup
Always
Setup
Always
Setup
Always
Setup
Always
Setup
Always
Setup
Always
Setup
Always
Setup
Always
Setup
Always
Cal
Always
Cal
Always
Cal
Always
Cal
Always
Cal
Always
Cal
Always
User
X250
User
Always
User
Always
User
Always
User
Always
User
Always
User
Always
User
Always
User
Always
User
Always
Seq
Com Mod
Seq
Always
Seq
Always
Seq
Always
Seq
Always
Seq
Always
Seq
Always
Seq
Always
Max Display Text Comment
1
0
2
135
70
225
0
0
1
0
0
1
65
20
200
0
0
30
0
0
30
0
0
2
0
0
100000
0
0
100000
0
0
100000
0
0
100000
0
0
10000
0
-7
7
0
-7
7
0
-20
10
0
-7
7
0
-7
7
0
0
1
110
50
220
10
3
70
15
0
59
0
0
30
0
0
10
0
0
59
0
0
10
0
0
0
0
0
1
0
0
2
0
0
3
0
0
100000
1
1
16
1
1
16
70
60
185
10
2
59
0
0
250
0
0
60
TROUBLESHOOTING-SUPERVISOR
Press Trans
250
P1 Max
250psi transducer
Water Switch
Water pressure switch enable for water
cooled machines
Oil Switch
Oil switch enable for flooded screw
machines
Min Load Psi
Minimum acceptable Loaded P1 value
Stop Timer
If not 0, run unloaded for this time before
stopping
Lube Cycle
Prelube/Postlube timer
K8 Option
Disable, Lube Pump, Master Control
Load Hours
Hours machine has been loaded
Run Hours
Hours machine has been running
Load Cycles
Number of load cycles
Starts
Number of starts
Capacity
Used by monitor to determine system load
P1
P2
dP1
P3
P4
Fault on Warn
Force shutdown on warning
Unload
250psi transducer unload pressure
Load Delta
Differential pressure from unload pressure
Unload Time
Auto mode shut down after unloaded for
this time
Drain Interval
Time between drains (Minutes)
Drain Time
Duration of drain (Seconds)
Restart Time
Auto restart on power up if not 0 (Seconds)
Wye Delta
Wye to delta starter transition time
(Seconds)
Language
French, German, Italian, Spanish, English
Temp Units
Fahrenheit, Celsius
Press Units
Pressure units, Psi, Bar, kPa
Sequence by
Disabled,Com, Hours, Remote, Slave,
Time Of Day etc.
Seq Hrs
Used for Hours sequencing mode
Com Number
Communications ID number
Machines
Number of machines in a system
Low Press
Panic start next machine in sequence
Recover Time
Keeps multiple machines from starting at
same time (seconds)
Rotate
Used to force a machine to stop
Minute
Real Time Clock Settings
Section 7