Dead Time Compensation

The "dead time compensation" function allows for compensation of the output voltage distorsion due to IGBT voltage
drop and its switching characteristics.
Distorsion of output voltage may cause non uniform, non smooth shaft rotation in open loop control.
It is possible to set a voltage value and the compensation variation, called Gradient, through the following parameters.
P.560 Deadtime cmp lev (Dead time compensation level)
Dead time compensation level.
P.561 Deadtime cmp slp (Dead time compensation slope)
Compensation gradient value.
Code
LCD display
P .560
Deadtime cmp lev
P .561
Deadtime cmp slp

Display Setting

P.580 Startup display
It is possible to define the first parameter that will be displayed at every power-on of the drive.
The choice can be carried out by setting the corresponding "IPA", reported in the parameters list table, into this
parameter.
P.600 Speed dsply fact (Speed display factor)
Costant used to convert frequencies to speeds.
The parameters is applied to the variable reported in the chapter DISPLAY, sections Basic and Encoder.
Code
LCD display
P .580
Startup display
P .600
Speed dsply fact
AGy-EV Instruction manual
v
Output voltage
+
Figure 7.6.18: Dead Time Compensation
[Code] & LCD select.
[Code] & LCD select.
Dead time slope
Dead time level
i
+
Voltage cmd to pwr
Default
MIN
(*)
0
(*)
0
Default
MIN
1
1
1
0.01
MAX
Unit
Variation
255
255
MAX
Unit
Variation
1999
99.99
0.01
Chapter 7 - Parameters Description • 179