Technical Data - Siemens SINAMICS S220 Equipment Manual

Booksize power units
Hide thumbs Also See for SINAMICS S220:
Table of Contents

Advertisement

5. Tighten the screw of the hose clamp using a suitable screw‐
driver.
6.1.7

Technical data

Table 6-11
Technical data 43 A and 72 A DC link adapter
Article number
Supply voltage
Current-carrying capacity at 55 °C
Conductor cross-section (flexible)
Booksize power units
Equipment Manual, 01/2022, 6SL3097-6AC30-0BP0
6. Fix the second conductor of the DC link connecting cable to
the mounting rail using a cable clamp.
Connect the cable for the DCP connection as described under
Points 2 to 5.
After installing the cables, ensure that the EMC contact plates
of the DC link adapter are in contact with the side panel of the
component.
The installed DC link connecting cable is shown in the adjacent
diagram.
6SL3162-
2BD00-0AA0
V
495 ... 720
DC
A
43
DC
mm
(AWG)
0.5 ... 10 (20 ... 6)
2
Accessories
6.1 DC link adapter
2BE00-0AA0
495 ... 720
72
10 ... 35 (8 ... 2)
89