3.4
S220 components and system data
3.4.1
Mixed operation of SINAMICS S120 and S220 modules
Overview
SINAMICS S120 and S220 components can be operated together in a drive lineup (mixed
operation).
Requirement
Danger to life due to unsuitable firmware version
Operating SINAMICS S220 Booksize components with an unsuitable firmware version can lead
to unsafe operating states. For example converter components can overheat, a motor can
unexpectedly accelerate or safety functions malfunction.
•
Description
The article numbers of SINAMICS S220 components start with 6SL5.
In mixed operation, the article numbers of SINAMICS S220 components are displayed with the
compatible article numbers of SINAMICS S120 components in the engineering tools (e.g.
Startdrive).
Table 3-1
Example in the engineering tools (e.g. Startdrive)
Article number on the
nameplate
6SL5130-6UE21-6AC0
6SL5130-6UE21-6AD0
For more information on compatible components, please refer to the SINAMICS S220/S120
compatibility list Compatibility list
109806050).
Booksize power units
Equipment Manual, 01/2022, 6SL3097-6AC30-0BP0
WARNING
Use a Control Unit with firmware V5.2 SP3 HF10 or higher.
Displayed article number of the compatible
component with respect to the Control
Units/firmware version
6SL3130-6TE21-6AA8
6SL5130-6UE21-6AD0
3.4 S220 components and system data
Remarks
The compatible article number of the SINAM‐
ICS S120 component is displayed.
If the component has no predecessor, the arti‐
cle number of the S220 component is dis‐
played.
(https://support.industry.siemens.com/cs/ww/en/view/
System overview
31