Reread delay time

It is used to prevent the same bar code from being read twice in succession. The reread delay setting is the minimum time interval that allows continuous reading of bar codes of the same type and data. The delay
It is only used in automatic code reading mode and continuous code reading mode. The set time range is 1 To 3600000 Milliseconds, default is 1000 millisecond. If the reread delay time is set greater than 3000
Milliseconds, the reread delay of the setting code will be limited to 3000 millisecond.
Set the reread delay time to 1000 Milliseconds, you can read the following barcodes in order to set:
【Reread delay time】
1. read " Startup settings "
2. Read " Reread delay time "
3. Data code "1" , "0" , "0" , "0" (See appendix-data code)
4. Read "Save" (see appendix-save or cancel)
5. read " Exit settings "