Click on the Monitor icon
6) On the SCU Monitor, check:
Throttle going from 0 to 100%
Map going from 1 to 5 using selector on the scooter
Brake Pressure sensor front, and rear are correctly connected
Boost signal goes from
Kill signal goes from
Boost Count
BoP Coefficient
MAPS SETUP AND CHECK
Each map (maximum 5 for each motor) can be set and shaped graphically. Each 10% throttle step can have its output
(%) selected through mouse cursor, simply by clicking on the desired value. User can therefore set 10 map breakpoints
individually for each map, whilst a linear interpolation will be automatically applied between those breakpoints.
It's important first to select the map number acting on external map selection buttons.
Once the map has been defined, it's possible to check output demand compliance by moving throttle from 0 to 100 % and verifying
green dot position on the map.
User can define separately 5 front and 5 rear maps. Maps are stored into SCU internal flash memory.
In defining each map, if the demand level exceeds Maximum Bop Map limit (see yellow line on graph), the applicable
demand will be capped and plot with continuous red line while the part of the same map exceeding the Bop level will be
still plotted but with dashed line (to highlight that it cannot be applied).
Monitor Icon
|
eSC S1-X – User manual
Select COM Port
48