J1 is a Schuko power socket 16A @ 250Vac with LED
-
J2 is the signals connector (Souriau UT001619PH)
-
J3 is the power connector (Amphenol PL082X-61-6)
-
F1 is the Fuse holder 30A @600V (15A fuse mounted)
The Status icon can be:
Green – No issue
Yellow – Warning
Red – Alarm
In the Dialog Window there are two lines of text.
The first line can be shown:
System ON – The system in ON
Charging – The system is ON and charging the battery
End of Charge – The battery is fully charge
The second line shown warnings and alerts:
Message
Min. Charging Voltage
Battery High Temp
Battery Low Temp. Charging
BMS High Temp.
Max Charging Current
NB:
Warnings do not affect the operation of the charger. Alarms intervene on the operation of the charger by
interrupting the charge.
|
eSC S1-X – User manual
Image 2117 - Charger's display overview
Warning
2,5V / cell
48 °C
5 °C
80 °C
26 A
Table 4 – Warnings & Alarms list
Alarm
2,4V / cell
50 °C
0 °C
85 °C
28 A