Ideal Heating LOGIC+ SYSTEM S18 Installation & Servicing page 5

Table of Contents

Advertisement

Table 1 - General Data
Boiler
Gas Supply
Gas Supply Connection
Injector Size
Flow Connection
Return Connection
Flue Terminal Diameter
Average Flue Temp-Mass Flow Rate
CO
Content (± 0.7)
2
Maximum Working Pressure (Sealed Systems)
Electrical Supply
Power Consumption
Fuse Rating
Water Content
Packaged Weight
Packaged Weight
Maximum Installation Weight
Maximium Installation Weight
Boiler Casing Size Internal
Boiler Casing Size External
Table 2 - Performance Data - Central Heating
Boiler
Boiler Input 'Q'
Boiler output
(non-condensing) Mean 70°C
Boiler output (condensing) Mean 40°C
Gas Consumption
Seasonal Efficiency*
Seasonal Boiler Efficiency*
NOx Classification
* The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by a notified body.
Note. Gas consumption is calculated using a
calorific value of 38.7 MJ/m
(1038 Btu/ft
3
or 34.9 MJ/m
(935 Btu/ft
) nett
3
3
To obtain the gas consumption at a different
calorific value:
a. For l/s - divide the gross heat input (kW) by
the gross C.V. of the gas (MJ/m
b. For m
/h - multiply l/s by 3.6
3
Installation and Servicing
SECTION 1 - GENERAL
(mm)
Central Heating
Central Heating
mm
Max. CH
Min. CH
kPa
Internal Boiler
External Boiler
Internal Boiler
External Boiler
Height
mm
Width
mm
Depth
mm
Height
mm
Width
mm
Depth
mm
Net CV
kW
Gross CV
kW
kW
kW
MJ/h
SEDBUK 2005
SEDBUK 2009
) gross
3
Key to symbols
AU = Australia
PMS = Maximum operating pressure of water
C
C
C
)
3
13
33
18
Natural Gas at 1.13kPa
1/2"
4.15
3/4"
3/4"
100
58°C - 8g/s
9.2%
8.6%
250
230 V ~ 50 Hz.
W
78
External: 3A
Internal: T4A HRC L250 V
litre
1.2
kg
31.5
kg
46.8
kg
26.1
kg
43.2
700
395
278
905
425
450
18
30
Min
Max
Min
Max
4.9
18.1
6.1
30.4
5.4
20.1
6.7
33.7
4.8
18.0
6.1
30.3
5.1
19.1
6.4
31.0
18.5
71.43
23.01
119.41
91.1%
89.7%
89.6%
CLASS 6
NZ = New Zealand
= A room sealed appliance designed for connection via ducts to a
53
horizontal or vertical terminal, which admits fresh air to the burner
and discharges the products of combustion to the outside through
orifices which, in this case, are concentric. The fan is up stream of
the combustion chamber.
30
4.65
69°C - 13g/s
8.9%
8.7%
100
31.5
46.8
26.1
43.2
(Countries of destination)
5

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LOGIC+ SYSTEM S18 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Logic+ system s30

Table of Contents

Save PDF