Appendix : Adam-6000W Mode Setting
switch
Mode 1 (Normal Mode): In this mode, you can use Utility to configure module to Infrastructure or Ad hoc
Mode 2 (Diagnostic Mode): The purpose of this mode is used to recover the Adam-6000W module from
Diagnostic-mode default settings:
Diagnostic
Diagnostic
mode.
error state. User can switch module to diagnostic Infrastructure/Ad hoc mode that
has temporary wireless setting and default IP, subnet mask. Therefore, user can
re-configure the wireless setting when module's communication is dead.
the temporary wireless setting will be cleared after reboot to Normal
Ad hoc mode setting:
Temporary
SSID: WLAN
Temporary
Channel: 10
Temporary
Wep: No
IP: 10.0.0.1
Subnet mask: 255.0.0.0
Gateway: 0.0.0.0
Infrastructure mode setting:
Temporary
SSID: <ANY>
Temporary
Channel: 10
Temporary
Wep: No
IP: 10.0.0.1
Subnet mask: 255.0.0.0
Gateway: 0.0.0.0
(*Note: