Operating Instructions and Parts Manual
Model
JSU50
Pipe Size
1
1
1
1
2"
1
2
WIRING CHART - RECOMMENDED WIRE AND FUSE SIZES
Fuse
Rating
HP
Volts
Amps
1/2
120
15
230
10
FRICTION LOSS CHART
Feet Friction Loss in 100 Feet of Plastic Pipe
20
25
⁄
"
5.6
8.5
11.9
4
⁄
"
2.6
4.0
2
1.2
1.6
⁄
"
2
Distance, in Feet, From Motor to Supply
(AWG Wire Size)
0
51
50
100
14
14
14
14
Gallons Per Minute
30
40
50
60
20.2
30.5
5.5
9.4
14.3
19.9
2.8
4.2
5.8
9.9
1.2
1.8
2.5
5
101
201
200
300
12
10
14
14
80
100
120
34.2
15.0
21.2
4.2
6.3
8.8
www.waynepumps.com