14.2
Flip-Flop Operation
Two beacons can be mounted close to each other to form a
flip-flop operation, where the beacons will flash alternately.
To achieve this mode of operation, fit a pin header to the flip-
flop header pins on the electronics board, i.e. the two header
pins are shorted together, (see figure 10) on one of the two
beacons. The first flash on the beacon that has the header
fitted will be delayed by ½ second. The two beacons will then
flash alternately every ½ a second.
15) Interchangeable & Spare Parts
Warning – Hot surfaces. External surfaces
and internal components may be hot after
operation, take care when handling the
equipment.
The beacon cover is interchangeable, contact E2S Ltd for a
replacement cover available in various colours.
To change the cover, unscrew the M5 socket head screws
and remove the M5 screws, M5 spring & flat washers.
Fig. 11 Removal of cover
Remove the guard and replace the old cover with the new
cover.
Old
Cover
Fig. 12 Changing of cover
_______________________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH
Document No. D210-00-211-IS
M5x16 Hex
Socket Screw
New
Cover
Issue 3
20-04-2020
Fit the guard back on to the cover and casting, align the
holes of the guard, cover and casting. To reattach the cover,
the fixings MUST be in the order shown in figure 12.
Fig. 13 Cover and Guard Fixtures

16) Maintenance, Overhaul and Repair

Maintenance, repair and overhaul of the equipment should
only be carried out by suitably qualified personnel in
accordance with the current relevant standards:
EN60079-19
Explosive atmospheres - Equipment repair,
overhaul and reclamation
IEC60079-19
EN 60079-17
Explosive
installations inspection and maintenance
IEC60079-17
To avoid a possible ELECTROSTACTIC CHARGE the unit
must only be cleaned with a damp cloth.
Units must not be opened while an explosive atmosphere is
present.
If opening the unit during maintenance operations a clean
environment must be maintained and any dust layer removed
prior to opening the unit.
Flameproof threaded joints and cemented joints are not
intended to be repaired.
sales@e-2-s.com
www.e-2-s.com
Sheet 5 of 5
M5x16 Hex Socket Screw
M5 Spring Washer
M5 Plain Washer
Guard
Cover
atmospheres
-
Electrical
Tel: +44 (0)208 743 8880
Fax: +44 (0)208 740 4200