[2] AIR CONDITIONER OPERATION IN THERMISTOR ERROR

* These models have following thermistors
INDOOR UNIT
OUTDOOR UNIT
TH1, TH2
TH1, TH2, TH3, TH4, TH5
The errors for the thermistors that are not mentioned above are irrelevant.
These indoor units don't have power relay.
These models don't have Heating operation.
1.Indoor unit
Item
Mode
Room tempera-
Auto
ture thermistor
(TH1)
Cooling
Dehumidifying
Heating
Heat exchanger
Cooling
thermistor (TH2)
Dehumidifying
Heating
2.Outdoor unit
Item
Mode
Compressor
Cooling
discharge
Dehumidifying
thermistor
Heating
(TH1)
Heat exchanger
Cooling
thermistor (TH2)
Dehumidifying
Heating
When resistance
is low (tem-
Control opera-
perature judged
tion
higher
actual)
Operation mode
Cooling mode is
judgment
activated even if
room temperature
is low.
Frequency con-
Room becomes
trol
too cold.
Room tempera-
Normal operation. Room temperature is
ture memory
Frequency con-
trol
Frequency con-
Room does not
trol
become warm.
Freeze preven-
Indoor unit
tion
evaporator may
freeze.
Cold air preven-
Cold air preven-
tion Cold
tion deactivates
too soon and cold
air discharges.
When resistance is
Control opera-
low (temperature
tion
judged higher than
actual)
Expansion valve
Compressor operates,
control and com-
but room does not
pressor protec-
become cool or warm
tion
(expansion valve is
open).
Outdoor unit heat
Compressor operates
exchanger over-
at low speed or stops.
heat prevention
Expansion valve
Defrosting operation
control Defrost-
is not activated as
ing
needed, and frost ac-
cumulates on outdoor
unit (expansion valve is
closed).
Climate Class 6100i / 6000i / 8100i / 8000i
Short-circuit
than
Cooling mode is activat-
ed in most cases.
Air to air conditioner
operates in full power
even when set tempera-
ture is reached.
stored in memory as
31.0°C, and compressor
does not stop.
Hot keep status results
immediately after opera-
tion starts.
Frequency does not
increase above
30 Hz (40 Hz).
Indoor unit evaporator
may freeze.
Compressor operates
at low speed or stops,
and frequency does not
increase.
Short-circuit
Compressor high
temperature error
indication.
Outdoor unit
thermistor
short-circuit error
indication.
Outdoor unit
thermistor
short-circuit error
indication.
4-3
When resistance
is high (tem-
perature judged
Open-circuit
lower than actu-
al)
Heating mode is
Heating mode is
activated even if
always activated.
room temperature
is high.
Room does not
Compressor does not
become cool.
operate.
Normal operation. Room temperature is
stored in memory as
18.5°C, and compres-
sor does not operate.
Room becomes
Air conditioner oper-
too warm.
ates in full power even
when set temperature
is reached.
Compressor
Compressor does not
stops occasional-
operate.
ly.
Cold air preven-
Cold air prevention
tion deactivates
does not deactivate,
too slow.
and indoor unit fan
does not rotate.
When resistance is
high (temperature
Open-circuit
judged lower than
actual)
Layer short-circuit
Outdoor unit therm-
or open-circuit may
istor open-circuit
result in compressor
error indication.
in normal operation.
Normal operation.
Outdoor unit therm-
istor open-circuit
error indication.
Defrosting operation
Outdoor unit therm-
is activated unnec-
istor open-circuit
essarily, and room
error indication.
does not become
warm (expansion
valve is open).