180Deg. Energizing Control - Bosch CLC6101i-W 50 HE Service Manual

Air/air heat pump
Table of Contents

Advertisement

Climate Class 6100i / 6000i / 8100i / 8000i

[4] 180deg. Energizing Control

This is the control system to moderate the speed by the current phase difference for higher efficiency and lower noise of the compressor. The current
phase difference control is the control system paid attention to the interrelation between efficiency and phase gap generated by the applied voltage
of motor and current in the coil of motor as shown in the figure below.
This control is the forced magnetization system independent of the location of rotor, detecting the phase difference between driving voltage phase
and line current phase flowing in motor coil, and controls the modulation rate data to get the phase difference at the best efficiency.
3-6