Milesight IoT Cloud, it allows users to monitor the flow of people and trigger linkage to control other devices via browser or mobile App remotely. VS132 can be widely used in entrances or corridors of retail stores, malls, offices, subways, etc.
Rate Indicator (Green) 10 Mbps mode 2.4 Dimensions (mm) 3. Power Supply VS132 can be powered by 802.3at standard PoE or power adapter (12VDC, 2A). If the both interfaces are connected, the device will be powered by the former method (PoE).
Powered by a PoE Injector 4. Access the Sensor VS132 sensor provides user-friendly web GUI for configuration and users can access it via Wi-Fi connection or Ethernet port. The recommended browsers are Internet Explorer, Firefox, Chrome, Microsoft Edge, and Safari. The default IP of Ethernet port is 192.168.5.220, the default IP of Wi-Fi is 192.168.1.1, and default SSID is People Counter_XXXXXX.
4.2 Access with Ethernet Step 1: Power on the device and connect the Ethernet port to a PC. Step 2: Change the IP address of computer to 192.168.5.0 segment as below: Go to Start Control Panel Network and Internet Network and Sharing Center...
Enter an IP address that in the same segment with sensor ( e.g. 192.168.5.61, but please note that this IP address shall not conflict with the IP address on the existing network); Step 3: Open the Browser and type 192.168.5.220 to access the web GUI. After logging on web GUI successfully, user is allowed to view configuration page.
Enable Tracks When enabled, there is tracking line when people pass the detection area. 5.2 Configuration 5.2.1 Rule Rule Configuration Users can set the rules and ROI to ensure accurate counting. Parameters Description Deploy Height Set the device deploy height from the ground. Set the deploy angle based on horizontal surface.
Page 11
Pass Area ROI Region of interest (often abbreviate ROI), is a selected subset of samples within a dataset identified for a particular purpose. Users can select entrance area and exit area to record the people count values which indicate the number of people passing from one area to another. Step 1: Click Set Entrance Area or Set Exit Area.
Click to clear all saved data records. 5.2.3 Communication 5.2.3.1 Ethernet VS132 provides a Ethernet port for wired access. Besides, users can get the people counting data or configure the device via CGI. For CGI document, please contact with Milesight IoT support: iot.support@milesight.com.
Page 13
Parameters Description IPv4 Address Set the IPv4 address of the Ethernet port, the default IP is 192.168. IPv4 Subnet Netmask Set the Netmask for the Ethernet port. IPv4 Default Gateway Set the gateway for the Ethernet port's IPv4 address. Preferred DNS Server Set the primary IPv4 DNS server.
Page 14
Parameters Description Enable Enable Wi-Fi feature. Work Mode Work mode is fixed as AP and can not connect to other access point. SSID The unique name for this device Wi-Fi access point. Protocol 802.11b (2.4 GHz), 802.11g (2.4 GHz), 802.11n (2.4 GHz) are optional. Bandwidth 20 MHz or 40 MHz are optional.
Page 15
Parameters Description Join Status LoRaWAN network joining status of this device. ® Device EUI Unique ID of the device, which can also be found on the label. App EUI The Default App EUI is 24E124C0002A0001. Application Port The port used for sending and receiving data, default port is 85. Join Type OTAA and ABP mode are available.
Page 16
Device Address DevAddr for ABP mode, the default address is the 5 to 12 digits of SN. Network Session Nwkskey for ABP mode, the default key is 5572404C696E6B4C6F52613230313823. Application Appskey for ABP mode, the default key is Session Key 5572404C696E6B4C6F52613230313823. LoRaWAN Version V1.0.2, V1.0.3, V1.1.0 are available.
5.2.4 System Basic Information All information about the hardware and software can be checked on this page. Time Configuration Parameters Description Time Zone Choose the time zone for your location. NTP Timing Sync the time with NTP server. Time Interval Set the interval to sync time with NTP server.
Page 18
computer time User Management Parameters Description Click to type administrator password, then set three security questions for your device. In case that you forget the password, you can click Forget Password button on login page to reset the password by answering three security questions correctly.
Page 19
Click the admin on the user list, then you can click Modify to change the login password of this device. Modify System Maintenance Description Parameters Language English or simplified Chinese are optional. Reboot Restart the device immediately. Basic Recovery: keep the IP settings, user information and stored counting data when resetting.
6. Installation Instruction Parameter definition: Parameters Explanation Value Installation height ≤3 m Minimum detection distance of VS132 0.5 m Δd Distance measurement error of VS132 0.05 m Maximum pedestrian height Example 1.8 m Minimum pedestrian height Example 1.6 m α...
5.43 × 3.44 2.09 × 1.32 5.64 × 3.57 2.30 × 1.46 5.85 × 3.71 2.51 × 1.59 6.06 × 3.84 2.72 × 1.72 6.27 × 3.97 2.92 × 1.85 6.3 Environment Requirements Black floor/carpet may affect the depth map to produce a lot of noise, but will not affect the ...
Page 22
Ceiling Mount Embedded Mount Wall Mount...
Besides, the device can be mounted with the mounting stand via the threaded hole. Note: Tilt installation should be avoided. Ensure that the front of the device and the ground plane parallel. Two devices should be avoided being installed too close since the ToF light from one device ...
1 Byte M Bytes 1 Byte For decoder examples please find files on https://github.com/Milesight-IoT/SensorDecoders. 7.1 Uplink Data VS132 reports basic information of sensor whenever joining the network and the number of people according to settings. Channel Type Description 01 (Protocol Version) 01=>...
(Periodic 02 = 2 Counter) Out: 01 00 => 00 01 =1 7.2 Downlink Command VS132 supports downlink commands to configure the device. Application port is 85 by default. Channel Type Description 10 (Reboot) ff (Reserved) 04 (Confirm Mode)
Page 26
2. Set AU915 or US915 channel mask as 8-15. ff0501ff00 ff05020000 ff05030000 ff05040000 ff05050000 Channel Type Value 01: Channel index 0-15, ff00 => 8-15 is enabled (Set Channel Mask) 02-05: Channel index 16-79, 0000 => all disabled 3. Reboot the device. ff10ff Channel Type...
Need help?
Do you have a question about the VS132 and is the answer not in the manual?
Questions and answers