• 1 Exterior Siren Output of 1.4A, 12VDC. Supervised in case of short-circuit or
disconnection.
• 4 Siren Output through PGM.
NOTE: Take into account the current values when connecting a siren to a
programmable output as these are not supervised when there is an excess in
consumption.
Programmable Outputs (PGMs)
The system has 4 programmable outputs of the open collector type and 16
different operation modes.
PGM1, PGM2 and PGM3 support up to 50mA.
PGM4 supports up to 500mA.
Power Supply Requirements
Transformer: 16.5 VAC, 25VA.
Battery: 12 volts, 4Ah minimum.
Regulated Power Supply
2 independent power supply outputs: AUX and AUX-3G/IP
• Supply: AUX 700mA, 12 VDC
• Supply: AUX-3G/IP 300mA, 12 VDC
EEPROM Memory
It does not lose the programming or the system status if a complete power outage
occurs.
Specifications of Remote Keypads (keypads KPD-800/KPD-860/KPD-860RF/
G-LED732/G-LCD732/G-LCD732RF)
• They are connected through 4 cables.
• Internal piezoelectric buzzer with volume control.
• Brightness control of the backlight (only for models KPD-860/KPD-860RF/
G-LCD732/G-LCD732RF).
• Microphone with integrated preamplifier for Audio Check (only for models
KPD-800/KPD-860/KPD-860RF).
• Built-in radiofrequency receptor (only for model KPD-860RF/G-LCD732RF).
• Anti disarming and dismantling tamper
• Independent indicator of the partitions status.
• Independent away arming, stay arming and disarming keys to facilitate use.
Communication protocols
• Residential SMS (only with COM-900)
• SDC2 (included by WiFi and optional by mobile networks with COM-900)
• DC1 (included by WiFi and optional by mobile networks with COM-900)
• Residential (included by WiFi and optional by mobile networks with COM-900)
Characteristics of system supervision
• AC power fault (in panel)
• AC power fault (in auxiliary source FRA-200)
• Low Battery Status (in panel)
• Low Battery Status (in auxiliary source FRA-200)
• Auxiliary power supply fault
• Fault by zone (supervised zones)
• Lack of programming of the internal clock
• Failure in the Siren output (disconnection and overcurrent)
• Failure of communication through mobile data (only with COM-900)
• Failure of communication by SMS
• Link failure
• Low battery by zone (only with wireless sensors)
• Zone tamper (only with wireless sensors)
• Keypads tamper
• Supervision of modules installed in BUS-D485 and BUS-C485.
• Failure in fire zones
• Characteristics of prevention against false alarms
• Audible Exit delay with differentiated sound in the last 10 seconds
• Audible entry delay
• Double shoot alarm for zones
• Burglary alarm in Cross zones
• Entry/Exit independent timing for each partition
• Auto arming and auto disarming with programmable dates and times
independent for each partition.
• Inactivity auto arming in zones with programmable times.
• Manual test of communication activated by keypad.
• Automatic test of communication programmable with start time and intervals.
• All modules are connected to the system through a Bus of 4 cables up to 200
meters from the PC-900G® panel.
• An event buffer of 512 records with the date and time when they occurred.
The buffer can be viewed with keypads KPD-860/860RF and G-LCD732/732RF
• Automatic shutdown: in case of an AC power outage and of considerably low
battery, the panel will automatically shut down and will restart when the AC power
supply is restored
• Swinger shutdown: programmable counters independent for 13 different types
of failures and/or alarms
• Force arm for local and/or remote arming modes
• Re transmission of Test Report and/or Network Failure programmable on time in
case of a communication failure

1.2 Additional devices

KPD-860RF/G-LCD732RF LCD keypad with wireless receptor.
The wireless receptor is integrated in each keypad and can be used to connect to
the system up to 24 wireless sensors, 64 remote controls identifiable among each
other and 4 PGM-W/MA-220G.
2-Way Wireles System® communication system.
All wireless sensors work at 434 MHz and are bidirectional supervised devices that
use CR123A lithium batteries.
NOTE: Keypads KPD-860RF/G-LCD732RF should be assigned the addresses between
1 to 4.
If a KPD-860RF/G-LCD732RF keypad is assigned an address higher than 4,
the keypad will annul its RF receptor.
The available devices are the following:
• Wireless movement detector DGW-500. It adds wireless protection of space to a
specific part of the place
• Wireless universal transmitter DGM-300. It adds door or window wireless
contacts to your system.
• Module of wireless programmable exit PGM-W/MA-220G: it allows, with no need
of interconnection of cables, to command lights, engines, automatic watering
among many other devices.
• Wireless remote control TX-500
The three keys of the remote control can be set up for different functions.
These are:
• System arming and disarming
• Partition panic button
• Activation of a PGM output
• Activation of PGM-W./MA-220G output.
COM-900 Cellular communicator
The cellular communicator is optional and it adds one more means of
communication to the alarm panel PC-900G. It can be used in two different ways:
• Report through WiFi as main channel and cellular network as backup channel
• Report through cellular network as main and only channel
WiFi Communicator
The embedded WiFi communicator included in the PC-900G will use an Internet
connection to communicate through the different methods of reporting.
It can also be used in three different ways:
• As main communicator
• As backup communicator
• As simultaneous communicator
Please refer to the instructions on different communication scenarios, backup
scenarios and scenarios for double or simultaneous report.
COM-900 Communicator
The modular communicator COM-900G adds one more means of communication to
the family of panels PC-900G. The connection method is "modular" and is inserted in
the female socket present in the central station.
It can also be used in three different ways:
• As main communicator
• As backup communicator
• As simultaneous communicator
For more information, see section 7 on page 12