Command number 297: Partition No. 4 Auto-disarm days
Default values -------------------------------> 0
2
9
Positions --------------------------------------> (1)
Command number 298: Keypad enabling
Default values ----------------------> 1
2
9
8
Positions -----------------------------> (1)
Digit position (1): Keypad No. 1
0 = Disabled
1 = Enabled
Digit position (2): Keypad No. 2
0 = Disabled
1 = Enabled
Digit position (3): Keypad No. 3
0 = Disabled
1 = Enabled
Digit position (4): Keypad No. 4
0 = Disabled
1 = Enabled
Digit position (5): Keypad No. 5
0 = Disabled
1 = Enabled
Digit position (6): Keypad No. 6
0 = Disabled
1 = Enabled
Digit position (7): Keypad No. 7 / Access control Part 1 & 2
0 = Disabled
1 = Enabled
Digit position (8): Keypad No. 8 / Access control Part 3 & 4
0 = Disabled
1 = Enabled
Comando Número 299: Module enabling
Default values ----------------------> 0
2
9
9
Positions -----------------------------> (1)
Digit position (1): Expander module No. 1 enabling
0 = Disabled
1 = Enabled
Digit position (2): Expander module No. 2 enabling
0 = Disabled
1 = Enabled
Digit position (3): Expander module No. 3 enabling
0 = Disabled
1 = Enabled
Digit position (4): Auxiliary source enabling
0 = Disabled
1 = Enabled
Digit position (5): Mobile data communications module enabling
0 = Disabled
1 = Enabled
Digit position (6): WiFi network communications module enabling
0 = Disabled
1 = Enabled
Digit position (7): Reserved for Future use
0 = Future use
1 = Future use
Digit position (8): Reserved for Future use
0 = Future use
1 = Future use
Command number 310: Subscriber number for events of Partition No. 1
Default values -------------------------------------------->
3
Positions --------------------------------------------------->
Digit positions (1) - (4): Subscriber number for events of Partition No. 1
The code must have 4 digits. Valid values are 0-F
Command number 311: Subscriber number for events of Partition No. 2
Default values -------------------------------------------->
3
Positions --------------------------------------------------->
28
0
0
0
0
7
(2)
(3)
(4)
(5)
0
0
0
0
(2)
(3)
(4)
(5)
(6)
0
0
0
0
(2)
(3)
(4)
(5)
(6)
0
0
1
0
(1)
(2)
0
0
1
1
(1)
(2)
Digit positions (1) - (4): Subscriber number for events of Partition No. 2
0
0
The code must have 4 digits. Valid values are 0-F
Command number 312: Subscriber number for events of Partition No. 3
(6)
(7)
Default values -------------------------------------------->
0
0
0
Positions --------------------------------------------------->
Digit positions (1) - (4): Subscriber number for events of Partition No. 3
The code must have 4 digits. Valid values are 0-F
(7)
(8)
Command number 313: Subscriber number for events of Partition No. 4
Default values -------------------------------------------->
Positions --------------------------------------------------->
Digit positions (1) - (4): Subscriber number for events of Partition No. 4
The code must have 4 digits. Valid values are 0-F
Command number 314: Subscriber number for System events
Default values -----------------------------------------> 0
Positions ------------------------------------------------> (1)
Digit positions (1) - (6): Subscriber number for System events
The code must have 6 digits. Valid values are 0-F
Command number 340: Time of First transmission of Periodic test report
Default values ---------------------------------------------->
Positions -------------------------------------------------->
Digit positions (1) - (4): Time of First transmission of test report
Valid values are 0-9. The time must be entered in 24-Hour format.
Command number 345: Reports 1
0
0
0
Default values ----------------------> 1
(7)
(8)
Positions ------------------------------> (1)
Digit position (1): Alarm report /Zone restoral/Police verification
0 = Not reported
1 = Reports Using Scenario No. 1
2 = Reports Using Scenario No. 2
Digit position (2): Zone Alarm cancellation report
Same options as in Alarms reports/Zone restoral
Digit position (3): Emergency keys report
Same options as in Alarms reports/Zone restoral
Digit position (4): Duress reports
Same options as in Alarms reports/Zone restoral
Digit position (5): Zone Inhibit/not inhibit report
Same options as in Alarms reports/Zone restoral
Digit position (6): User enabling/disabling report
Same options as in Alarms reports/Zone restoral
Digit position (7): Keyswitch enabling/disabling report
Same options as in Alarms reports/Zone restoral
Digit position (8): Network failure/Restoral report
Same options as in Alarms reports/Zone restoral
Command number 346: Reports 2
Default values --------------------->
Positions ----------------------------> (1)
0
0
Digit position (1): Battery trouble/restoral report
0 = Not reported
1 = Reports Using Scenario No. 1
(3)
(4)
2 = Reports Using Scenario No. 2
Digit position (2): Future use
Digit position (3): Future use
Digit position (4): RF Sensors failure/supervision restoral report
Same options as in Battery trouble/restoral report
Digit position (5): Low battery in RF Sensors report
0
0
Same options as in Battery trouble/restoral report
Digit position (6): Programming entry/exit report
(3)
(4)
Same options as in Battery trouble/restoral report
3
1
2
3
1
3
3
1
4
3
4
0
1
1
3
4
5
(2)
(3)
1
1
1
3
4
6
(2)
(3)
0
0
0
0
(1)
(2)
(3)
(4)
0
0
0
0
(1)
(2)
(3)
(4)
0
0
0
0
0
(2)
(3)
(4)
(5)
(6)
0
0
0
0
(1)
(2)
(3)
(4)
1
1
1
1
1
(4)
(5)
(6)
(7)
(8)
1
1
1
1
1
(4)
(5)
(6)
(7)
(8)

Advertisement

Table of Contents
loading

Related Products for Garnet PC-900G

Table of Contents