SECTION 1: Introduction to the system

This manual is designed to help you throughout the installation process of the Alarm
Panel PC-900G®. We suggest that you read the complete manual before starting the
installation process so you can better understand all this security system has to offer.
This manual is not designed for the end user. End users are advised to read the User
Manual provided with the system. If you have any questions regarding the procedures
described in this manual, please enter www.garnet.com.ar/Soporte_Tecnico/Consultas

1.1 Specifications

Programming
• Local programming through keypads.
• Local programming through PC-LINK wire (adapter cable).
• Remote programming through WiFi and COM-900® with AC4 software and with
Garnet Programmer App.
Partitions
The system has 4 independent partitions and the possibility of sharing zones in
any of them, thus obtaining partitions with zones that are common to 4 partitions.
Flexible Configuration of Zones
• 32 completely programmable zones with 19 different function settings and 8
different attributes, one for each.
• 1 additional zone for each installed keypad
• Zone loop with simple EOLR
• Fire zones with flaw and alarm discrimination
• By using EXP-8Z zone expanders the system supports up to 24 additional
hardwired zones (maximum of 3 expanders)
• With KPD-860RF/G-LCD732RF keypads (one is enough), the system supports up
to 24 wireless zones (within the 32 available).
• Cross zones
• Group Inhibition Zones
4
16.5 VAC
25 VA
50/60 Hz
Red +
Black -
- AUX +
EXP-8Z
STATUS
RUNNING
E1
C E2 E3 C E4 E5 C E6 E7 C E8
+ BELL -
+ BUS -
A
B PGM1 PGM2 PGM3 PGM4 Z1
Watch connected
of PGM
SIREN
KEYBOARDS
1.4A Max.
+ BUS - A B
Codes
The system has 42 codes available for the following functions:
• 1 master code
• 31 user codes
• 4 duress codes (one for each partition)
• 1 installer code
• 1 code for local programming through adapter cable (PC-Link)
• 4 codes for remote control through SMS (Using COM-900)
Data Bus: BUS-D485
It works through protocol RS-485, its connection is done with 4 cables, 2 for power
supply and 2 for data. The system is capable of supervising each device connected
to the Bus and generating a flaw when there is an error condition. The maximum
connection distance between the panel and the devices is 200 mts.
• It supports up to 8 keypads
• 3 EXP-8Z Expander Modules
• 1 Auxiliary source 1.5A FRA-200
• 1 Adapter Cable for local programming (PC-Link)
Modular Connection
It is especially designed for the transmission of events through cellular network.
The PC-900G has a female on header to which the additional COM-900 module is
connected and provides an additional communication channel.
Audible Alarm Output
The system supports up to 5 alarm outputs using the combination among
Programmable Outputs (PGMs) and the Exterior Siren Output.
Each programmable output can be set up as siren output for any of the 4 partitions,
thus obtaining 4 siren outputs (each independent to each partition) and an exterior
siren output common to all 4 partitions through the Siren Output of the panel.
The sound of the siren is continuous or pulsed in case of fire alarm.
The fire alarm can be set up to be Pulsed (1 second turned on, 1 second turned off) or
temporary 3, according to the NFPA 72 standard (500mS turned on, 500mS turned off,
500mS turned on, 500mS turned off, 500mS turned on, 1.5 seconds turned off).
ANT WIFI COMUNIC
ANT WIFI
COMUNIC
SIGNAL 1-5
ACK
NO SIGNAL
NAK
C
Z2
Z3
C
Z4
Z5
C
Z6
N.O.
N.O.
N.C.
Z MIC
RFL
RFL
RFL
2.2K
2.2K
2.2K
RFL
2.2K
Magnetic
Z7
C
Z8
N.C.
RFL
2.2K

Advertisement

Table of Contents
loading

Table of Contents