Command number 251: Manual test report counter
Default values -----------------------------------------------------------------------------> 0
Positions -------------------------------------------------------------------------------------> (1)
Digit position (1)- (2): Manual test report counter
The code must have 2 digits. Valid values are from 00 to 16 events.
Command number 252: WiFi module failure counter
Default values ------------------------------------------------------------------------------> 0
Positions -------------------------------------------------------------------------------------> (1)
Digit position (1)- (2): WiFi module failure counter
The code must have 2 digits. Valid values are from 00 to 16 events.
Note: If you program 00, the equipment will not supervise the trouble.
Command number 253: Network failure counter
Default values ----------------------------------------------------------------------------->
Positions -------------------------------------------------------------------------------------> (1)
Digit position (1)- (2): Network failure counter
The code must have 2 digits. Valid values are from 00 to 16 events.
Note: If you program 00, the equipment will not supervise the trouble.
Command number 254: Zone alarm counter
Default values -----------------------------------------------------------------------------> 0
Positions -------------------------------------------------------------------------------------> (1)
Digit position (1)- (2): Zone alarm counter
The code must have 2 digits. Valid values are from 00 to 16 events.
Note: If you program 00, the equipment will not supervise the trouble.
Command number 255: Keypad supevision failure counter
Default values ------------------------------------------------------------------------------> 0
Positions -------------------------------------------------------------------------------------> (1)
Digit position (1)- (2): Keypad supevision failure counter
The code must have 2 digits. Valid values are from 00 to 16 events.
Note: If you program 00, the equipment will not supervise the trouble.
Command number 256: Mobile data module failure counter
Default values -----------------------------------------------------------------------------> 0
Positions ----------------------------------------------------------------------------------->
Digit position (1)- (2): Mobile data module failure counter
The code must have 2 digits. Valid values are from 00 to 16 events.
Note: If you program 00, the equipment will not supervise the trouble.
Command number 259: Tamper alarm counter
Default values -----------------------------------------------------------------------------> 0
Positions -------------------------------------------------------------------------------------> (1)
Digit position (1)- (2): Tamper alarm counter
The code must have 2 digits. Valid values are from 00 to 16 events.
Note: If you program 00, the equipment will not supervise the trouble.
Command number 260: Partition No. 1 options
Default values ----------------------> 0
2
6
0
Positions -----------------------------> (1)
Digit position (1): Chime sound in Away Arm
0 = Disabled
1 = Enabled
Digit position (2): Chime sound in Stay Arm
0 = Disabled
1 = Enabled
Digit position (3): Force arm by Keypad, Keyswitch and Remote controls
0 = Disabled
1 = Enabled
Digit position (4): Force arm for Automatic and/or remote arming
0 = Disabled
1 = Enabled
26
2
5
1
2
5
2
2
5
3
2
5
4
2
5
5
2
5
6
(1)
2
5
9
0
0
0
0
0
(2)
(3)
(4)
(5)
(6)
(7)
Digit position (5): Future use
0 = Future use
8
1 = Future use
Digit position (6): Future use
(2)
0 = Future use
1 = Future use
Digit position (7): Auto-arm enable due to idle time (inactivity)
0 = Disabled
1 = Enabled
Digit position (8): Future use
8
0 = Reserved for Future use.
1 = Reserved for Future use.
Note: Commands 261 to 263 (Partition options) are programmed as Command
(2)
No. 260.
Command number 261: Partition No. 2 options
Default values ----------------------> 0
2
Positions -----------------------------> (1)
0
8
Command number 262: Partition No. 3 options
Default values ----------------------> 0
(2)
2
Positions -----------------------------> (1)
Command number 263: Partition No. 4 options
Default values ----------------------> 0
8
2
Positions -----------------------------> (1)
(2)
Command number 270: Panel (I) options
Default values ----------------------> 0
2
Positions -----------------------------> (1)
Digit position (1): Future use
8
0 = Future use
1 = Future use
Digit position (2): Future use
(2)
0 = Future use
1 = Future use
Digit position (3): Siren response in case of Keychains TX-500 panic
0 = Panic Silent
1 = Panic Audible
Digit position (4): Fire siren sound
8
0 = Pulsed
1 = Temporal 3
Digit position (5): Hide panic emergency message
(2)
0 = Disabled
1 = Enabled
Digit position (6): Siren hit of Wireless sensor tampers
0 = Disabled
1 = Enabled
Digit position (7): Enable Energy saver mode
0 = Disabled
8
1 = Enabled
Digit position (8): Installer code blocked
(2)
0 = Disabled
1 = Enabled
Command number 271: Panel (II) options
Default values ----------------------> 0
2
0
0
Positions -----------------------------> (1)
Digit position (1): Zone bypasss without code
0 = Disabled
(8)
1 = Enabled
Digit position (2): PGMs control without code
0 = Disabled
1 = Enabled
Digit position (3): Quick Arm/Disarm
0 = Disabled
1 = Enabled
Digit position (4): Double hit (in the same zone)
0 = Disabled
1 = Enabled
0
0
0
6
1
(2)
(3)
(4)
0
0
0
6
2
(2)
(3)
(4)
0
0
0
6
3
(2)
(3)
(4)
0
0
0
7
0
(2)
(3)
(4)
0
0
0
7
1
(2)
(3)
(4)
0
0
0
0
(5)
(6)
(7)
(8)
0
0
0
0
(5)
(6)
(7)
(8)
0
0
0
0
(5)
(6)
(7)
(8)
0
0
0
0
(5)
(6)
(7)
(8)
0
0
0
0
(5)
(6)
(7)
(8)