[12] 24-Huor Water zone
This type of zone is used in places where there is a need to prevent floods. If the zone
is violated, an instant alarm will be generated notwithstanding if the system is armed
or disarmed.
[13] Zone Follower
This zone will generate no alarm if violated during an entry delay period. If the delay
period ends, the zone will generate an alarm.
If the zone is hit and the panel is in entry delay status, an instant alarm will be
generated.
Este tipo de zona sólo funciona con el sistema armado.
[14] Interior and Follower zone
This zone will generate no alarm if violated during an entry delay period. If the delay
period ends, the zone will generate an alarm.
If the zone is hit and the panel is not in entry delay status, an instant alarm will be
generated.
This type of zone only works with the system armed.
The zones programmed as interior will be automatically cancelled when the user Stay
arms the system to enable the free movement within the premises.
[15] Keyswitch zone for Partition No. 1
The momentary violation of this zone will alternately arm or disarm the status of
Partition No.1.
[16] Keyswitch zone for Partition No. 2
The momentary violation of this zone will alternately arm or disarm the status of
Partition No. 2.
[17] Keyswitch zone for Partition No. 3
The momentary violation of this zone will alternately arm or disarm the status of
Partition No. 3.
[18] Keyswitch zone for Partition No. 4
The momentary violation of this zone will alternately arm or disarm the status of
Partition No. 4.

5.3 Zone attributes

Additional zone attributes may be programmed to turn a zone operation for a specific
application.
The following attributes are programmable for each zone:
Swinger Shutdown: This attribute determines if the zone will automatically cancel
for reports and siren hit once the repeated alarm counter reaches its threshold (see
command [254] Zone alarm counter).
Excludable: This attribute determines if the zone may or may not be manually
excluded (Bypassed) (see section 3.6 Function keys).
Partition assignment No. 1: This function defines a zone as belonging to partition
No 1.
Partition assignment No. 2: This function defines a zone as belonging to partition
No. 2.
Partition assignment No. 3: This function defines a zone as belonging to partition
No. 3.
Partition assignment No. 4: This function defines a zone as belonging to partition
No. 4.
Sound: This attribute determines if the zone will turn on (Audible) or not the alarm
output (Silent).
Response speed: This attribute determines if the zone works on 50mS or 500 mS.
Zone attributes are programmed in Commands [110] – [141].
5.4 Cross zone
The control panel includes a cross zone option that requires the hitting of two or
more zones within a programmable period of time in order to start an alarm
transmission sequence.
On the other side, if the option "Double hit in the same zone" is enabled, it will
generate an alarm transmission sequence if the zone is violated twice during the
programmed period of time. The same effect will be generated if the zone remains
open during all the programmed period of time as "Time interval for Cross zones".
See Commands [142]-[145] and [163].

5.5 Group inhibition zone

The zones defined as group inhibition zones may be automatically inhibited by
pressing the key [
] for 3 seconds.
See Commands [146]-[149].
NOTE: Only available on KPD-860/KPD-860RF/G-LCD732/G-LCD732RF keypads.

5.6 Keypad zone assignment

KPD-800/KPD-860/KPD-860RF/G-LED732/G-LCD732/G-LCD732RF keypads have a zone
entry to which a device, such as a door contact, may be connected. (See Section 2.10
"Keypad zones" for more information regarding wiring).
Once the keypad zones are installed, assign the zones to the programming com-
mands [200]-[207].
NOTE: If the zones assigned to keypads range between zones 1-8, they will cancel the
PC-900G® board zones.
10

5.7 Information download

The required Information download software is AC4.
The information download may be performed in 4 different manners:
• Through a PC-Link adapter cable and the pc, no need to use a MODEM.
• Using the COM-900G module as programmer.
• Using the WiFi board module as programmer.
5.8 Options for PGM output
Program the programmable outputs (PGM1, PGM2, PGM3 and PGM4 in the main
panel) selecting one of the output options listed below.
[00] No. 1 partition armed indicator: The output will remain on while partition 1 is
armed.
[01] No. 2 partition armed indicator: The output will remain on while partition 2 is
armed.
[02] No. 3 partition armed indicator: The output will remain on while partition 3 is
armed.
[03] No. 4 partition armed indicator: The output will remain on while partition 4 is
armed.
[04] Maintained output command: The output may be used as keyswitch.
The change in status may be controlled with a keypad (see section 3.5 "[
PGM output control") or by using software AC4.
NOTE: The output may be controlled by sending a text message through the COM-900
module.
[05] Pulse output command: The output delivers a pulse. Such pulse may be hit
through a keypad (see section 3.5 "[
by using software AC4.
NOTE: The output may also be controlled by sending a text message through the
COM-900 module.
[07] Siren sound pulse: The PGM will emit a pulse each time the siren sounds.
[08] Partition No. 1 siren: The PGM turns into a partition siren. Each time an alarm is
generated in such partition, the PGM will be enabled during the siren period of time
programmed for such partition.
[09] Partition No. 2 siren: The PGM turns into a partition siren. Each time an alarm is
generated in such partition, the PGM will be enabled during the siren period of time
programmed for such partition.
[10] Partition No. 3 siren: The PGM turns into a partition siren. Each time an alarm is
generated in such partition, the PGM will be enabled during the siren period of time
programmed for such partition.
[11] Partition No. 4 siren: The PGM turns into a partition siren. Each time an alarm is
generated in such partition, the PGM will be enabled during the siren period of time
programmed for such partition.
[13] Mobile data communication failure: The PGM will be enabled in case of Mobile
data communication failure.
[15] Battery trouble: The PGM will be enabled in case of battery trouble.
[16] Network failure: The PGM will be enabled in case of network failure.
[17] Auxiliary power supply trouble: The PGM will be enabled in case of auxiliary
output power supply trouble.
[18] Smoke detectors adjustment: The PGM will remain enabled and will be
disabled for 3 seconds from the time the [
output control") is entered.
NOTE: The PGM outputs cannot be fully disabled in installer programming. To fully
disable a PGM output you shall remove the whole wiring.