Digit position (7): Clock adjust report
Same options as in Battery trouble/restoral report
Digit position (8): Keypad Tamper/RF sensors report
Same options as in Battery trouble/restoral report
Command number 347: Reports 3
Default values --------------------->
3
4
7
Positions ----------------------------> (1)
Digit position (1): Test report (Manual and Automatic)
0 = Not reported
1 = Reports Using Scenario No. 1
2 = Reports Using Scenario No. 2
Digit position (2): Follower test report
Same options as in Test report
Digit position (3): Auxiliary trouble
Same options as in Test report
Digit position (4): Auto-arm/Auto-disarm report
Same options as in Test report
Digit position (5): Auto-arm due to inactivity report
Same options as in Test report
Digit position (6): Manual test report
Same options as in Test report
Digit position (7): Siren output failure report
Same options as in Test report
Digit position (8): Keypad/Expander and Auxiliary source supervision failure
Same options as in Test report
Command number 350: Future use.
Command number 360: Periodic test reports transmission counters
Default values --------------------------------------------->
3
Positions -------------------------------------------------->
Digit position (1): Periodic test transmission counter
0 = Minutes counter
1 = Hours counter
2 = Days counter
Digit position (2): Follower test transmission counter
0 = Minutes counter
1 = Hours counter
2 = Days counter
Digit position (3): Future use
0 = Future use
1 = Future use
2 = Future use
Digit position (4): Future use
0 = Future use
1 = Future use
2 = Future use
Command number 361: Time interval of Periodic test report
Default values ------------------------------------------------------------------->
Positions ------------------------------------------------------------------------->
Digit positions (1) - (3): Time interval of Periodic test report
The must have 3 digits. Valid values are de from 000 to 255
Note: Program 000 to cancel the Telephone test report
Command number 362: Time interval of Follower test report
Default values ------------------------------------------------------------------->
Positions ------------------------------------------------------------------------->
Digit positions (1) - (3): Time interval of Follower test report
El command debe tener 3 digits. Valid values are from 000 to 255
1
1
1
1
1
(2)
(3)
(4)
(5)
(6)
1
0
6
0
(1)
(2)
3
6
1
(1)
3
6
2
(1)
Command number 370: Call No. 1 scenario (Reports with backup)
Default values --------------------->
Positions ----------------------------> (1)
Digit position (1): Main output means
1
1
1
0 = Future use
1 = Future use
2 = Future use
(7)
(8)
3 = Reports to Mobile data monitoring
4 = Reports to WiFi monitoring
5 = End of backups
Digit position (2): First Backup of Main output means
Same options as in Main output means
Digit position (3): Second Backup of Main output means
Same options as in Main output means
Digit position (4): Third Backup of Main output means
Same options as in Main output means
Digit position (5): Fourth Backup of Main output means
Same options as in Main output means
Digit position (6): Fifth Backup of Main output means
Same options as in Main output means
Digit position (7): Sixth Backup of Main output means
Same options as in Main output means
Digit position (8): Seventh Backup of Main output means
Same options as in Main output means
Command number 371: Call No. 2 scenario (Simultaneous reports)
Default values --------------------->
Positions ----------------------------> (1)
0
0
Digit position (1): Transmit through Telephone No. 1
0 = Disabled
1 = Enabled
(3)
(4)
Digit position (2): Transmit through Telephone No. 2
0 = Disabled
1 = Enabled
Digit position (3): Transmit through SMS - Residential
0 = Disabled
1 = Enabled
Digit position (4): Reports to monitoring through Mobile data
0 = Disabled
1 = Enabled
Digit position (5): Reports to monitoring through WiFi network
0 = Disabled
1 = Enabled
Digit position (6): IP-Residential
0 = Disabled
1 = Enabled
Digit position (7): Future use
0 = Future use
1 = Future use
Digit position (8): Future use
0
2
4
0 = Future use
1 = Future use
(2)
(3)
Command number 400: Zone assignment for Wireless sensor in Memory position
No. 1
Default values -----------------------------------------------------------------------------> 0
Positions -------------------------------------------------------------------------------------> (1)
0
0
0
Digit positions (1) - (2): Zone number for sensor recorded in Memory
position No. 1.
The command must have 2 digits. Valid values are from 00 to 32
(2)
(3)
Note: Commands 401 t 423 (Zone assignment for Wireless sensors) are
programmed as Command No. 400.
Important: Only keypads with Address 1, 2 , 3 and 4 work as receivers.
0
5
0
3
7
0
(2)
(3)
0
0
0
3
7
1
(2)
(3)
0
0
0
0
0
(4)
(5)
(6)
(7)
(8)
0
0
0
0
0
(4)
(5)
(6)
(7)
(8)
0
4
0
0
(2)
29