8–8
Model 2100 and 2200 Ultra SCSI Controller Enclosures User Guide

Power Supply

In redundant power supply configurations, follow hot-pluggable procedures; otherwise,
follow power-off procedures. See Figure 8–6 as needed during the removal and
installation. Complete the procedure in Table 8–6 to remove a power supply. Complete the
procedure in Table 8–7 to install a power supply.
Figure 8–6. Power supply removal and installation
1.
For hot-pluggable, go to step 4. For power-off, proceed to step 2.
2.
Shut down the array controllers using array controller documentation.
3.
Disconnect the power cord from the power supply (see Figure 8–6).
4.
Disengage and remove the power supply from the enclosure.
5.
Disconnect the fan from the power supply.
CAUTION: The enclosure requires power supplies rated for at least 180 W.
Table 8–6 Removing a Power Supply