Removal And Installation Procedures; Table 8-1 Element Replacement Methods And Procedures - Compaq StorageWorks 2100 User Manual

Ultra scsi controller enclosures
Table of Contents

Advertisement

Removal and Installation Procedures

Table 8–1 identifies the replacement methods and replacement procedures for each
enclosure element. In all cases, a power-off replacement method is possible.
Table 8–1 Element Replacement Methods and Procedures
Element
EMU
Hot-pluggable
I/O Module
Pluggable
Power Supply
Hot-pluggable (redundant power supply configuration)
ECB Battery Pack
Power-off only
ECB
Array controller dependent:
Pluggable
Fan
Hot-pluggable
Array Controller
Pluggable
Cache Module
Pluggable
1. Requires using the field replacement utility (FRUTIL). Refer to array controller documentation for
replacement procedures.
2. Applies only to dual-redundant controller configurations. Requires using FRUTIL. Refer to array
controller documentation for replacement procedures.
3. Applies to all single-controller configurations, and dual-redundant controller configurations without
FRUTIL support.
Recommended Replacement Method
1
1
or hot-pluggable
2
3
or power-off
2
3
or power-off
CAUTION: If a conflict exists between the replacement procedures within this
document and those within array controller-specific documentation, use procedures
in the array controller documentation.
Removal and Installation Procedures
Replacement Procedures
Table 8–2 and Table 8–3
Table 8–4 and Table 8–5
Table 8–6 and Table 8–7
Table 8–8
Table 8–9 and Table 8–10
Table 8–11 and Table 8–12
Table 8–13 and Table 8–14
Table 8–13 and Table 8–14
8–3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 2200

Table of Contents