Assembly With A Gemü Weldolet; Assembly With A Gemü In-Line Housing; Assembly With A Gemü Wafer Type Fl Ange - GEM mFlow 3030 Quick Manual

Magnetically inductive flowmeter
Hide thumbs Also See for mFlow 3030:
Table of Contents

Advertisement

2.1.1
Assembly with a
GEMÜ weldolet
CAUTION
Weld in the weldolet without the fl owmeter!
Locking
wing
Figure 1
Figure 3
Mounting depth L is calculated as follows:
L = 79 - S - T
S = Wall thickness of pipeline
T = Please refer to the table of mounting
dimensions for the respective pipeline
size
Figure 2
Table of mounting
dimensions
DN
T [mm]
25
4.5
32
6.0
40
7.2
50
8.3
65
10.0
80
12.0
100
14.5
125
17.5
150
20.5
200
27.0
250
33.0
300
39.5
Further dimensions
on request
9 / 20
1. Bore a hole ø 33 in the pipeline.
2. Lodge the weldolet (fi gure 1) in the hole.
3. Align the locking wings at 90° to the fl ow
direction (fi gure 2).
4. Weld the weldolet with the mounting
dimensions "T" corresponding to the
nominal size (fi gure 3) perpendicular
to the pipeline axis (please refer to the
mounting dimensions table).
5. Insert the fl owmeter into the weldolet
when cooled (make sure the locking
wings do not become twisted).
6. Attach the fl owmeter to the weldolet
using the union nut (M33x2, SW36).
2.1.2
Assembly with a
GEMÜ in-line housing
1. Attach the in-line housing to the line.
2. Insert the fl owmeter into it (make sure
the locking wings do not become
twisted).
3. Attach the fl owmeter to the in-line
housing with the union nut
(M33x2, SW36).
2.1.3
Assembly with a
GEMÜ wafer type fl ange
1. Attach the wafer type fl ange (with an
O-ring) to the line.
2. Insert the fl owmeter into it (make sure
the locking wings do not become
twisted).
3. Attach the fl owmeter to the wafer
type fl ange with the union nut
(M33x2, SW36).
3030

Advertisement

Chapters

Table of Contents
loading

Table of Contents