GEM mFlow 3030 Quick Manual

GEM mFlow 3030 Quick Manual

Magnetically inductive flowmeter
Hide thumbs Also See for mFlow 3030:
Table of Contents

Advertisement

Quick Links

3030
Flow
m
Magnetisch-Induktiver Durchfl ussmesser
Magnetically Inductive Flowmeter
ORIGINAL QUICK GUIDE
DE
QUICK GUIDE
GB
3030

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for GEM mFlow 3030

  • Page 1 3030 Flow Magnetisch-Induktiver Durchfl ussmesser Magnetically Inductive Flowmeter ORIGINAL QUICK GUIDE QUICK GUIDE 3030...
  • Page 2: Table Of Contents

    ® Link abrufbar ist: https://www.gemu-group.com/ Richtig webcode/?webcode=GW-3030 Montage Lufteinschlüsse Montage allgemein Vor dem Einbau des GEMÜ 3030 Flow in die Rohrleitung die Rohrleitung entleeren und soweit abkühlen, dass Verätzungen durch Medium und Verbrühungen ausgeschlossen sind. Falsch 3030 2 / 20...
  • Page 3 Hinter dem GEMÜ 3030 Flow darf sich Um Verwirbelungen durch kein freier Auslauf befi nden, damit die Leitungskrümmungen zu vermeiden, die das Rohrleitung immer komplett befüllt ist. Messergebnis verfälschen können, sollte eine gerade Einlaufstrecke von 10 x DN und eine gerade Auslaufstrecke von 5 x DN Richtig vorgesehen werden.
  • Page 4: Montage Mit Gemü Einschweißhülse

    2.1.1 Montage mit GEMÜ 1. Bohrung ø 33 in Rohrleitung bohren. Einschweißhülse 2. Einschweißhülse (Abbildung 1) in die Bohrung stecken. VORSICHT 3. Arretierungsnase 90° zur Durchfl ussrichtung ausrichten Einschweißhülse nicht mit eingebautem (Abbildung 2). Durchfl ussmesser einschweißen! 4. Einschweißhülse mit dem der Nennweite entsprechenden Einbaumaß...
  • Page 5: Montage Mit Tuchenhagen

    2.1.4 Montage mit Tuchenhagen 2. Durchfl ussmesser mit aufgeschweißter Varivent In-Line Gehäuse Verschlussplatte auf das BioControl ® ® Durchgangsgehäuse setzen. Wichtig: 3. Auf richtige Ausrichtung des Die Elektroden des Sensors Sensors achten (Elektroden 90° zur müssen immer genau quer zur Durchfl...
  • Page 6: Ändern Von Parametern

    Ändern von Parametern Inbetriebnahme Beim GEMÜ 3030 Flow werden mit Hilfe Der Durchfl ussmesser GEMÜ 3030 Flow Tasten die verschiedenen ist werkseitig kalibriert und somit nach Menüs ausgewählt. Anlegen der Betriebsspannung sofort Die Veränderung der gewünschten betriebsbereit. Parameter geschieht mit Hilfe von Folgende Einstellung sollten vorgenommen Klammern, die um den betreff...
  • Page 7 fl ow. Installation in a downpipe Assembly should be avoided if possible. General assembly information Ensure that the pipe-lines are always fi lled. 2.1.1 Assembly with a GEMÜ weldolet 2.1.2 Assembly with a GEMÜ in-line housing 2.1.3 Assembly with a GEMÜ wafer type fl ange 2.1.4 Assembly with a Tuchenhagen...
  • Page 8 Upstream of the GEMÜ 3030 Flow no free In order to avoid turbulence as a result outlet is allowed to ensure that the pipeline of pipe bending which can falsify the is always completely fi lled. measurement results, a straight inlet...
  • Page 9: Assembly With A Gemü Weldolet

    T [mm] (M33x2, SW36). 2.1.3 Assembly with a GEMÜ wafer type fl ange 10.0 1. Attach the wafer type fl ange (with an O-ring) to the line. 12.0 2. Insert the fl owmeter into it (make sure 14.5...
  • Page 10: Assembly With A Tuchenhagen Varivent In-Line Housing

    2.1.4 Assembly with a 1. Weld BioControl in-line housing into the ® Tuchenhagen Varivent pipeline. ® in-line housing 2. Put the fl owmeter with the welded cover plate into the BioControl in-line housing. ® Important: 3. Observe correct alignment of the sensor The sensor electrodes must always (electrodes 90°...
  • Page 11: Changing Parameters

    Changing parameters Commissioning keys are used for the GEMÜ The GEMÜ 3030 Flow fl owmeter is 3030 Flow to select the various menus. calibrated at the factory and therefore ready When changes to the parameters are for operation when the operating voltage is required brackets are put around the values.
  • Page 12: Confi Guration Menu (Setup)

    Konfi gurationsmenü Confi guration menu (Setup) (setup) Menüstruktur Menu structure 1. Service 1. Service Service I / O Status Login Diagnosis 3030 specific r0w- Version 1.1.1.1 r0w0 r0w- Error List hrs. XXXXX:XX:XX r0w0 r1w1 r1w1 Code: Logout? NewCode:1 Active Level: 3 0...1000 0...10000 Nur verfügbar bei Geräteausführung MT2...
  • Page 13 Return r0w- S/N 743984/ Return Seriennummer r0w3 r0w3 Warnings Clear Error List Return On...Off r2w2 r3w3 NewCode:2 NewCode:3 Return 0...10000 0...10000 ung MT2 Nur verfügbar bei Geräteausführung MT2 rendelkezésre Csak MT2 készülékkivitel esetén áll rendelkezésre Only available in Device Version MT2 r0w3 r0w- r0w-...
  • Page 14 Menüstruktur Menu structure 2. SetBasics 2. SetBasics Csak készülékkivitel esetén áll rendelkezésre l/min m³/min GAL/min* gal/min** Q+TQ1 BBL/min*** Q+TQ2 bbl/min**** v+TQ1 m³/h v+TQ2 GAL/h* gal/h** TQ1+TQ2 BBL/h*** bbl/h**** 3030 14 / 20...
  • Page 15 3030 15 / 20...
  • Page 16 Menüstruktur Menu structure 3. SetFunction 3. SetFunction A rendelkezésre állás a K3 Fn beállítástól függ 3030 16 / 20...
  • Page 17 I out onWar A rendelkezésre állás a K1 Fn beállítástól függ K1 delay A rendelkezésre állás a K2 Fn beállítástól függ K2 delay Csak akkor áll rendelkezésre, ha K3 Fn = impulzusok Csak akkor áll rendelkezésre, ha PulseOutput = impulzus/l Csak akkor áll rendelkezésre, ha PulseOutput = l/impulzus K3 delay 3030 17 / 20...
  • Page 18 Menüstruktur Menu structure 4. SetCalibration 4. SetCalibration Csak akkor áll rendelkezésre, ha típusok = GEMÜ Csak akkor áll rendelkezésre, ha típusok = GEMÜ 3030 18 / 20...
  • Page 19 3030 19 / 20...
  • Page 20: Operation

    German version of this document is the Im Zweifelsfall oder bei Missverständnissen authoritative document! ist die deutsche Version des Dokuments ausschlaggebend! GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG · Fritz-Müller-Str. 6-8 · D-74653 Ingelfi ngen-Criesbach Telefon +49(0)7940/123-0 · Telefax +49(0)7940/123-192 · info@gemue.de · www.gemu-group.de...