General Specifications; Safe Practices; Measurement Specifications - Klein Tools IR5 Instruction Manual

Dual-laser infrared thermometer, dual-laser targeting, 12:1 distanceto-spot ratio, auto-scan, max/min/avg/diff, high/low alarm, backlit display, auto power-off, adjustable emissivity
Hide thumbs Also See for IR5:
Table of Contents

Advertisement

Available languages

Available languages

ENGLISH

GENERAL SPECIFICATIONS

Klein Tools IR5 is a professional dual-laser targeting infrared
thermometer. It offers a wide measurement range, a tight distance-
to-spot ratio, dual targeting lasers, and several calculation modes to
facilitate different temperature measurement applications.
• Operating Altitude: 6562 ft. (2000 m)
• Relative Humidity: <85% non-condensing
• Operating Temp: 32° to 122°F (0° to 50°C)
• Storage Temp: -4° to 140°F (-20° to 60°C)
• Measurement Range: -22° to 752°F (-30° to 400°C)
• Units: Settable to °F or °C
• Emissivity: 0.10-1.00 adjustable
• Optical Resolution (Distance-to-spot): 12:1
• Dimensions: 6.83" x 4.53" x 1.85" (173 x 115 x 47 mm)
• Weight: 9.84 oz. (279 g) including battery
• Battery Type: 1 x 9V battery
• Battery Life: (Estimates assume 9V Zinc-Carbon Battery)
10 hours continuous use w/laser and backlight on.
• Display: Backlit LCD with white backlight
• Display Resolution: 0.1°F (0.1° C)
• Calibration: Accurate for one year
• Lasers: FDA and IEC Class II
• Standards: Certified to IEC EN 61326-1:2013, EN 61326-2-3:2013,
IEC EN 60825-1:2014
Complies with 21 CFR 1040.10 and 1040.11 except for
conformance with IEC 60825-1 ED. 3, as described in
Laser Notice No. 56 dated May 8, 2019
• Pollution degree: 2
• Drop Protection: 6.6 ft. (2m)
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.

MEASUREMENT SPECIFICATIONS

• Response Time: <250ms
• Data hold: Yes
• MAX/MIN/Average/Differential: Yes
• Spectral Response: 8000-14000nm
°F
°C
°F
°C
≥32
(≥0
)
±4
(±2
°F
±(4
+ 0.2
°F
°C
<32
(<0
)
°C
±(2.2
+ 0.2
• Repeatability: ±0.8% of reading or ±2°F(±1°C)
(whichever is greater).
• Temperature Correction Coefficient: ±0.2°F per °F (±0.1°C per °C), or
±0.2% of reading (whichever is greater) when ambient temperature is
above or below 70 – 77°F (21 – 25°C).
2
) or ±2% (whichever is greater)
°F
°F
per degree below 32
)
°C
°C
per degree below 0
)
Specifications subject to change.
To ensure safe operation and service of the meter, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Do not direct laser beam into eyes, as this can cause permanent
eye damage.
• Do not use the meter if the case is damaged in any way.
• Replace the battery as soon as low battery indicator appears.
• Thermometer is NOT intended for use on people or animals.
• Service the meter immediately if it is acting abnormally.
• Avoid using the meter around strong electromagnetic fields.
• BURN HAZARD. Reflective materials may have a higher actual
temperature than the measured temperature. Set emissivity to
match the object being measured (see Emissivity section).

SAFE PRACTICES

This meter is designed for professionals who understand the hazards
associated with their trade. While this meter causes no foreseeable dangers
beyond its targeting lasers; the objects being measured, as well as the
environment in which they reside, can be hazardous. Common safety
practices to follow when operating near temperature critical environments are:
• Follow the manufacturer's maintenance procedures when
servicing equipment.
• Before using this meter to determine if an area is safe, verify
correct operation by measuring a known temperature value of a
comparable object.
• Properly maintain this meter and calibrate it regularly.
Warning label on side of meter
WARNINGS
CAUTION
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents