FRONT OF UNIT
BACK OF UNIT
LCD DISPLAY
Klein Tools ET10 is a digital thermometer with a magnetic base that easily attaches to air vents for HVAC air temperature readings, and takes ambient and direct-contact readings in both Fahrenheit (°F) and Celsius (°C) scales.
Range | Accurate To |
-40 to -4°F (-40 to -20°C) | +/-3.6°F (+/- 2°C) |
-3 to 302°F (-19 to 150°C) | +/-2.7°F (+/- 1.5°C) |
Above 303°F (150°C) | +/- 2% |
NOTE: Although the thermometer can measure up to 572°F (300°C), the plastic body and sheath are rated only to 160°F (71°C). DO NOT expose thermometer to temperatures above 160°F (71°C); only the stainless steel probe can withstand temperatures above 160°F (71°C), and only for a short time.
Specifications subject to change.
To ensure safe operation and service of the thermometer, follow these instructions. Failure to observe these warnings can result in severe injury or death.
ON/OFF BUTTON
Press the Power Button to power on and off the thermometer.
AUTO POWER-OFF
Auto Power-Off will automatically turn off the meter after 15 minutes of inactivity. When powered on, Auto Power-Off is enabled by default. To disable the Auto Power-Off function, press and hold the MAX/MIN/AVG Button while powering on. The Auto Power-Off icon will disappear from the display. After powering off, the Auto Power-Off function will be enabled when powered on again; repeat this process to disable again.
°F/°C SELECT BUTTON
The thermometer's default measurement scale upon power-up is Fahrenheit (°F). Press the °F/°C button to toggle between Fahrenheit (°F) and Celsius (°C).
HOLD BUTTON
Press the HOLD button to lock the current reading on the display. Press again to return to active measurement mode.
MAX/MIN/AVG BUTTON
The MAX/MIN/AVG button toggles between (in order) Max, Min, Average (AVG), and Data Point modes. Data is refreshed with every entry.
To return to normal measuring mode, press the MAX/MIN/AVG button for more than two seconds.
BACKLIGHT
To activate the Backlight, press the MAX/MIN/AVG button and the °F/°C button simultaneously. Backlight will automativally deactivate after approx. 30 seconds; repeat this process to reactivate.
BATTERY REPLACEMENT
When the Low Battery indicator is displayed on the LCD, the batteries must be replaced.
NOTE: There are no user-serviceable parts inside thermometer.
Be sure thermometer is turned off and wipe with a clean, dry lint-free cloth. Do not use abrasive cleaners or solvents.
Remove the batteries when the meter is not in use for a prolonged period of time. Do not expose to high temperatures or humidity.
After a period of storage in extreme conditions exceeding the limits mentioned in the General Specifications section, allow the thermometer to return to normal operating conditions before using.
Do not place equipment and its accessories in the trash. Items must be properly disposed of in accordance with local regulations. Please see www.epa.gov or www.erecycle.org for additional information.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Klein Tools ET10 - Magnetic Pocket Thermometer Manual
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the ET10 that isn't answered in the manual? Leave your question here.