ENGLISH
GENERAL SPECIFICATIONS
The Klein Tools IR07 is a dual IR (infrared) Thermometer and probe Thermometer. It
features an IR Thermometer with laser targeting, a probe Thermometer with hook for
hands-free operation, and displays results in either Fahrenheit or Celsius scales.
• Environment: Indoor or outdoor
• Operating Altitude: 6561' (2000 m)
• Relative Humidity: < RH 85% non-condensing
• Operating Temperature: 32° to 122°F (0° to 50°C)
• Storage Temperature: -4° to 140°F(-20° to 60°C)
• Display: White Backlit LCD
• Display resolution: 0.1°F (0.1°C)
• Units: Selectable °F or °C
• Temp Coef cient: +/- 0.1°C or +/- 0.1% per °C, whichever is greater (21° to 25°C)
• IR Temperature Range: -40° to 572°F (-40° to 300°C)
• IR Temperature Resolution: 0.1°F (0.1°C)
• Distance to Spot Ratio: 8:1
• Emissivity: 0.95 fixed
• Response Time: <500ms
• IR Temperature Accuracy: +/- 2°C+ 0.1°C from -40° to 0°C
+/- 2°C or +/- 2% whichever is greater from 1° to 300°C
• Probe Temperature Range: -40° to 572° F (-40° to 300°C)
• Probe Temperature Resolution: 0.1°F (0.1°C)
• Minimum Probe Depth: 0.5" (12 mm)
• Probe Temp Accuracy: +/- 2°C from -40° to 0°C
+/- 1°C or +/- 1% whichever is greater from 1° to 300°C
• Laser: FDA and IEC Class 2
• Laser Power: < 1mW @ 1 cm
• Laser Wavelength: 630 to 670 nm
• Standards: Conforms to IEC EN 61326-1:2013, EN 61326-2-3:2013, EN60825-1:2014
• Power: 2 x 1.5V AAA batteries (included)
• Battery Life: IR: 30 hours (continuous use) Probe: 180 hours (continuous use)
• Dimensions: 5.8" x 0.96" x 1.6" (148 x 24 x 42 mm)
• Weight: 2.5 oz. (72 grams)
• Drop Protection: 6.6 ft. (2 m)
• IP rating: IP54
• Pollution Degree: 2
• Electromagnetic Environment: IEC EN 61326-1. This equipment meets
requirements for use in basic and controlled electromagnetic environments like
residential properties, business premises, and light industrial locations.
Specifications subject to change.
WARNINGS
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Do not direct laser beam into eyes, as this can cause permanent eye damage.
• Do not use the tester if the case is damaged in any way.
• Replace the battery as soon as low battery indicator appears.
• Replace the tester immediately if it is acting abnormally.
• Be cautious of readings of reflective materials as the tester may
indicate that these surfaces are cooler than their actual temperature.
• Thermometer is NOT intended for use on people or animals.
• Avoid using the tester around strong electromagnetic fields.
CAUTION
• BURN HAZARD. Reflective materials may have a higher actual temperature than the
measured temperature.
• DO NOT attempt to repair this tester. It contains no serviceable parts.
DO NOT attempt to repair this tester. It contains no serviceable parts.
DO NOT
• DO NOT expose tester to extremes in temperature or high humidity.
DO NOT
DO NOT expose tester to extremes in temperature or high humidity.
SAFE PRACTICES
This tester is designed for professionals who understand the hazards
associated with their trade. While this tester causes no foreseeable dangers
beyond its targeting lasers; the objects being measured, as well as the
environment in which they reside, can be hazardous. Common safety practices
to follow when operating near temperature critical environments are:
• Follow the manufacturer's maintenance procedures when servicing equipment.
• Before using this tester to determine if an area is safe, verify correct
operation by measuring a known temperature value of a comparable object.
ENGLISH
TESTER FEATURES
E
G
A
H
1.
SCAN/HOLD
button
2.
Differential
temperature
button (T1-T2)
3.
MAX/MIN button
4.
LCD display
LCD FEATURES
F
D
B C
A.
Targeting
laser active
B.
IR in use
C.
PROBE in use
D.
HOLD
ESPAÑOL
CARACTERÍSTICAS DEL PROBADOR
1. Botón SCAN/HOLD
(ESCANEAR/RETENER)
2. Botón de temperatura
diferencial (T1-T2)
NOTE: Increased
3. Botón MAX/MIN
distance from target
4"
may affect tester
(MÁXIMO/MÍNIMO)
accuracy.
(102 mm)
4. Pantalla LCD
NOTA: Si la
5. Sensor de
distancia desde el
temperatura IR
objetivo es mayor
a la indicada,
la precisión del
CARACTERÍSTICAS DE LCD
probador se puede
ver afectada.
A.
Láser de enfoque
del objetivo activado
REMARQUE :
Il est possible que
B.
IR en uso
les résultats soient
C.
SONDA en uso
moins précis si le
testeur se trouve
D.
RETENER
loin de la cible.
Warning or caution
Wear approved eye protection
Risk of electrical shock
Read instructions
Conformité Européenne: Conforms with European Economic
Area directives
UKCA:
UK Conformity Assessment
WEEE: Electronics disposal
8:1 OPTICAL RESOLUTION
The IR07 is configured with 8:1 optical resolution (distance-to-spot-ratio).
Typical diameters of the measurement area as a function of the distance
between the tester and the target area are shown in FIG. 2. NOTE: Increased
distance from target may affect tester accuracy.
MEASURING IR TEMPERATURE
Aim the tester at the object to be measured and push the SCAN/HOLD button
1
button
for at least 2 seconds. When button is released, "HOLD" will show
on the display, and the measurement will be held.
For Differential Temperature:
• Press the T1-T2 button
1
button
.
• Press the T1-T2 button
press SCAN/HOLD button button
• Press the T1-T2 button
temperature value on the screen.
• Long press T1-T2 button to exit.
MEASURING PROBE TEMPERATURE
Open the temperature probe using the thumb stud
NOTE: Do not open the probe by touching the metal part of the probe, as your
body temperature can effect the probe's temperature readings.
NOTE: The probe must be opened to an angle greater than 30 degrees before
measurement will start.
Press the SCAN/HOLD button
For Differential Temperature:
• Press the T1-T2 button
• Press the T1-T2 button
• Press the T1-T2 button
temperature value on the screen.
• Long press T1-T2 button to exit.
SELECTING A TEMPERATURE SCALE
The default scale is Fahrenheit (°F). Press and hold both the MAX/MIN
2
T1-T2
buttons for 2 seconds to change scale to Celsius (°C).
MAX/MIN:
Press the MAX/MIN button
minimum values being measured. Press to cycle through MAX, MIN, and
current reading. Long-press to exit. NOTE: The laser light will remain on in
IR MAX/MIN mode.
TARGETING LASER:
The laser is on when the SCAN/HOLD button
released. When on, the laser icon
FRANÇAIS
CARACTÉRISTIQUES
5.
IR temperature sensor
DU TESTEUR
6.
Target laser
1.
Bouton SCAN/HOLD (balayage/
7.
Temperature probe
maintien)
8.
Battery
2.
Bouton de température différentielle
compartment door
(T1-T2)
9.
Temperature probe
3.
Bouton MAX/MIN
thumb stud
4.
Écran ACL
5.
Capteur de température
à infrarouge
E.
Low battery
6.
Laser d'acquisition de la cible
indicator
7.
Sonde
F.
MAX / MIN
de température
G.
T1 / T2 / T1 - T2
8.
Couvercle du
H.
°F / °C
compartiment à piles
9.
Goujon de pouce de la sonde de
température
CARACTÉRISTIQUES DE
L'ÉCRAN ACL
A.
Laser d'acquisition de la cible
activé
6. Láser de enfoque
B.
Mode infrarouge en cours
del objetivo
d'utilisation
7. Sonda de
C.
Sonde en cours d'utilisation
temperatura
D.
Maintien activé
8. Tapa del
E.
Indicateur de
compartimento
piles faibles
de las baterías
F.
MAX/MIN
9. Perno para pulgar
G.
T1/T2/T1-T2
de la sonda
de temperatura
H.
°F/°C
E.
Indicador de
batería baja
F.
MÁX/MÍN
G.
T1 / T2 / T1 - T2
H.
°F / °C
SYMBOLS ON TESTER
OPERATING INSTRUCTIONS
2
to view T1, then press SCAN/HOLD button
2
again to lock in T1 value and enter T2, then
1
.
2
again to lock in T2 value and get the differential
9
to start measurement.
1
to lock in the measurement.
2
to view T1.
2
again to lock in T1 value and enter T2.
2
again to lock in T2 value and get the differential
3
to begin recording the maximum and
1
is held, and is off when
A
will be visible on the display.
Dual IR/Probe Thermometer – Instructions
Termómetro doble IR/sonda – Instrucciones (ver el otro lado)
Thermomètre double à infrarouge et à sonde – Instructions (voir l'autre côté)
• Pocket tester with backlit display measures temperature from -40° to 572°F (-40° to 300° C)
• Measure surface temperature using infrared thermometer with targeting laser (distance-to-
spot ratio = 8:1)
• Measure inside air vents and duct temperatures using temperature probe with hanging hook
• Quickly calculates differential temperature (T1-T2) for both IR and probe temperatures
• Functions include Hold, Max/Min, Auto-Power Off, and low battery indicator
• Probador de bolsillo con pantalla retroiluminada que mide temperaturas de -40 °F a 572 °F (-40 °C a 300 °C).
• Mide temperaturas en superficies utilizando el termómetro infrarrojo con láser de puntería (relación distancia
a objetivo = 8:1)
• Mide temperaturas en conductos y ventilaciones internas usando la sonda de temperatura con gancho para
colgar
• Calcula rápidamente la temperatura diferencial (T1-T2) del infrarrojo y de la sonda
• Incluye funciones como retención de datos, máximo/mínimo, apagado automático e indicador de batería baja
• Testeur de poche avec affichage rétroéclairé qui mesure les températures de -40 à 300 °C (-40 à 572 °F)
• Mesure la température de surface grâce au thermomètre à infrarouge avec laser de ciblage (rapport distance-
cible de 8:1)
• Mesure la température à l'intérieur des évents et des conduits grâce à la sonde avec crochet
• Calcule rapidement la température différentielle (T1-T2) des mesures prises par infrarouge ou avec la sonde
• Les fonctions comprennent : maintien, max./min., arrêt automatique et indicateur de piles faibles
OPERATING INSTRUCTIONS
NOTES:
• To conserve battery life, the auto-power off feature will automatically turn
off the tester when the probe is closed, and/or after 10 minutes of inactivity.
• If the display shows 'OL' following a measurement, this indicates that the
object being measured is either above or below the measurement range of
the tester.
BATTERY REPLACEMENT
When
indicator is displayed on LCD, batteries must be replaced.
8
1. Open the battery compartment
2. Remove 2 exhausted AAA batteries and dispose of appropriately.
3. Replace batteries and return battery compartment cover, ensuring that it
locks into place, then secure with screw.
CLEANING
Be sure tester is turned off and wipe with a clean, dry lint-free cloth.
Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when not in use for a prolonged period of time. Do
not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the General
Specifications section, allow the tester to return to normal operating
conditions before using.
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash.
Items must be properly disposed of in accordance with local
regulations. Please see www.epa.gov/recycle for additional
information.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street, Lincolnshire, IL 60069
1-800-553-4676
customerservice@kleintools.com
www.kleintools.com
3
and
IR07
.
1390453 Rev. 10/21 B

Advertisement

loading

Summary of Contents for Klein Tools IR07

  • Page 1 ENGLISH GENERAL SPECIFICATIONS SYMBOLS ON TESTER OPERATING INSTRUCTIONS The Klein Tools IR07 is a dual IR (infrared) Thermometer and probe Thermometer. It NOTES: features an IR Thermometer with laser targeting, a probe Thermometer with hook for Warning or caution • To conserve battery life, the auto-power off feature will automatically turn hands-free operation, and displays results in either Fahrenheit or Celsius scales.
  • Page 2 RESOLUCIÓN ÓPTICA 8:1 • Dimensiones: 5,8" x 0,96" x 1,6" (148 x 24 x 42 mm) El IR07 está configurado con una resolución óptica de 8:1 (relación distancia a objetivo). Se ilustran los • Peso: 2,5 oz (72 gramos) LIMPIEZA diámetros típicos del área de medición como función de la distancia entre el probador y el área objetivo...