WACON AquaInform Sycon 2500 Operating Manual page 6

On-line water hardness monitor
Table of Contents

Advertisement

• Analysis START
• Analysis Cycle
• Retry Cycle
• digital Input
• digital Outputs
• Reset-Functions
• Dimension
• Power Supply
• Indicator à 500 ml
• Maintenance Interval
Order Numbers
Limit Value-Indicator
Residual Hardness °dH H25
Order Number
Carbonate Hardness °dH C25
Order Number
L
A
IMIT
NALYSER
O
-
W
N
LINE
ATER
With limit Analyser, WACON offers a very compact and easily operated water
analyser for automatic on-line detection of hardness leakages and quality control
of water softeners. The system controls selectable limit values according to the
colorimetric principle. A broad range of functions (incl. BOB) guarantee reliable
field-operation. Units will be supplied in standard as well as tailor-made housings.
→ Detection of Hardness Leakages
Application:
→ Limit monitoring
pushing START – button
a) manually
b) automatically
in programmable intervals 5, 10, 20 or 30 minutes
→ via remote input signal (flow- or level-control switch)
→ Programmable rinsing phase 30 sec – 10 min.
→ Zero compensation without indicator injection (Self calibration)
→ Dosed injection of indicator via peristaltic pump and stirring of water sample
→ Monitoring and evaluation according to the colorimetric method
→ LED status indication of evaluation result
→ Rinsing and cleaning of mixing chamber / solenoid valve stops flow of sample water
→ Control monitoring 4 min. after first detection of hardness leakage
Potential free
e.g. for connecting timer or flow monitor
switch
-> no analysis if break-contact is open
• 2 x potential
→ REL 1
free Relays
→ REL 2
• Quit "Limit value alarm"
→ RELAY 1
• Quit „Failure" „Alarm"
→ RELAY 2
• Quit "Indicator refilled"
• Interruption/Stop of Analysis
W: 300mm
H: 300mm
85 – 264 V 47-63 Hz , Protection Category IP 54
• Consumption app. 0.10 ml/Analysis (5000 each bottle)
app. 2-3 times a year cleaning of mixing chamber
Once a year exchange of wearing parts
SYCON 2500
30-010120
Standard Housing 33-099005
1 mg/l
2 mg/l
4 mg/l
0,05
0,1
0,2
32-084125 32-084135 32-084145 32-084155 32-084165 32-084175 32-084185 32-084195 32-084205 32-084215
1
1,5
2
32-086125 32-086135 32-086145 32-086155
H
H
A
ARDNESS
NALYSER
automatic starts can be switched on/off
Limit value alarm (Permanent or Impulse)
• lack of Indicator (BOB-operation)
• fouling or electronic failure
Failure
• lack of water(pressure) or
incomplete reagent injection
D: 190mm
6 mg/l
10 mg/l
20 mg/l
0,3
0,5
1
3
Weight ca. 2 kg
• shelf life 24 month
• Annual-Service-Set
40 mg/l
60 mg/l
100 mg/l
2
3
5
200 mg/l
10