Vestil CBFC-DC Manual

Vestil CBFC-DC Manual

Powered lift counterbalanced floor cranes

Advertisement

Quick Links

TABLE OF CONTENTS
CBFC-DC Powered Lift Counterbalanced Floor Cranes
Receiving Instructions
After delivery, remove the packaging from the product. Inspect the product closely to determine
whether it sustained damage during transport. If damage is discovered, record a complete description
of it on the bill of lading. If the product is undamaged, discard the packaging.
NOTE: The end-user is solely responsible for confirming that product design, use, and maintenance
comply with laws, regulations, codes, and mandatory standards applied where the product is used.
Technical Service & Replacement Parts
For answers to questions not addressed in these instructions and to order replacement parts, labels,
and accessories, call our Technical Service and Parts Department at (260) 665-7586. The department
can also be contacted online at https://www.vestil.com/page-parts-request.php.
Electronic Copies of Instruction Manuals
Additional copies of this instruction manual may be downloaded from
manuals.php.
Signal
Words....................................................................................................................
Safety
Instructions..............................................................................................................
CBFC-500 & CBFC-1000 Exploded View & Bill of
CBFC-500 Rated Loads for Specified Boom
CBFC-1000 Rated Loads for Specified Boom Lengths
CBFC-2000 Exploded View & Bill of
CBFC-2000 Rated Loads for Specified Boom
Raising and Lowering the
Using the
Crane................................................................................................................
Air Purging
Procedure......................................................................................................
Boom Length
Adjustment..................................................................................................
Record of Satisfactory
Inspections &
Maintenance..............................................................................................
Troubleshooting...............................................................................................................
Labeling
Diagram.............................................................................................................
Limited
Warranty...............................................................................................................
TABLE OF CONTENTS
2999 North Wayne Street, P.O. Box 507, Angola, IN 46703
Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868
Table of Contents
Lengths.............................................................
Materials.......................................................................
Lengths............................................................
Boom.........................................................................................
Condition.......................................................................................
Copyright 2022 Vestil Manufacturing Co.
Rev. 4/22/2022
V
M
ESTIL
ANUFACTURING
Fax: (260) 665-1339
www.vestil.com
NOTE: A copy of the
MPU-DC Gen2 manual is
also necessary.
Materials.....................................................
..........................................................
CBFC, MANUAL
C
.
ORP
info@vestil.com
https://www.vestil.com/page-
Page
9
10
Page 1 of 12
2
2
3
4
5
6
7
8
8
9
9
9
-
10
-
11
11
12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CBFC-DC and is the answer not in the manual?

Questions and answers

Summary of Contents for Vestil CBFC-DC

  • Page 1 2999 North Wayne Street, P.O. Box 507, Angola, IN 46703 Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868 Fax: (260) 665-1339 www.vestil.com info@vestil.com CBFC-DC Powered Lift Counterbalanced Floor Cranes NOTE: A copy of the MPU-DC Gen2 manual is also necessary. Receiving Instructions After delivery, remove the packaging from the product.
  • Page 2: Signal Words

    SAFETY INSTRUCTIONS Vestil strives to identify foreseeable hazards associated with the use of its products, but no manual can address every conceivable risk. Minimize the likelihood of injury by observing the hazards identified below and by inspecting and maintaining the product as instructed in INSPECTIONS &...
  • Page 3 BOLT, PLAIN FINISH, GRADE A, 1/4- 20X1.5 PIN, WELDMENT, PIVOT, OUTER BOOM, 28-612-001 32030 HWH TEK DRILL &TAP CBFC 99-021-904- CYLINDER, HYDRAULIC, Ø1 1/2" x 18", RAM STYLE Page 3 of 12 TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co.
  • Page 4: Specifications

    300 lb. (136.4kg) 1in. = 2.54cm; 1kg = 2.2 lb. SPECIFICATIONS A specifications document for CBFC-500-DC floor cranes is available online to anyone who visits Vestil’s website. Specifications include dimensions, net weight, and capacity information. access appropriate specifications document, navigate...
  • Page 5 500 lb. (227.3kg) 1in. = 2.54cm; 1kg = 2.2 lb. SPECIFICATIONS A specifications document for CBFC-1000-DC floor cranes is available online to anyone who visits Vestil’s website. Specifications include dimensions, net weight, and capacity information. To access appropriate specifications document,...
  • Page 6 COTTER PIN Z PLATED, 3/16 x 2 CBFC CYLINDER, HYDRAULIC, Ø2" x 18" RAM 99-021-948 01-111-006 BUSHING, POLYGON 1 ID X 1 LG STYLE W/ CLEVIS MOUNTS 16-514-378 WELDMENT, FRAME, OUTER BOOM Page 6 of 12 TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co.
  • Page 7 1000 lb. (454.5kg) 1in. = 2.54cm; 1kg = 2.2 lb. SPECIFICATIONS A specifications document for CBFC-2000-DC floor cranes is available online to anyone who visits Vestil’s website. Specifications include dimensions, net weight, and capacity information. access appropriate specifications document, navigate...
  • Page 8: Raising And Lowering The Boom

    Always DOWN control button lower the boom until the load is entirely supported by the ground or other surface before leaving the crane. Page 8 of 12 TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co.
  • Page 9: Inspections & Maintenance

    Apply all relevant inspections as instructed in the MPU-DC GEN2 owner manual as well. (A) Before each use, inspect the following items: Page 9 of 12 TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co.
  • Page 10: Troubleshooting

    5. Have to keep l. Outlet check valve allowing oil l. Remove both outlet check valves. Clean pressing UP to return to pump chamber. valves. Score bottom of chamber for ball Page 10 of 12 TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co.
  • Page 11 C: Label 1157: Maximum rated load for each boom length (both sides of boom) Labeling D: Label 586 (on counterweight): use-related hazards Diagram MPU- DC GEN2 owner’s manual Page 11 of 12 TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co.
  • Page 12 After Vestil receives your request for warranty service, an authorized representative will contact you to determine whether your claim is covered by the warranty. Before providing warranty service, Vestil will require you to send the entire product, or just the defective part (or parts), to its facility in Angola, IN.

Table of Contents