Example For Mintime/Maxtime Logic - netvox RA02C User Manual

Wireless co detector
Hide thumbs Also See for RA02C:
Table of Contents

Advertisement

Description
Device CmdID
Config
0x01
ReportReq
Config
0x81
ReportRsp
RA02C
ReadConfig
0x02
ReportReq
ReadConfig
0x82
ReportRsp
(1) Command Configuration:
MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v
Downlink: 0111003C003C0100000000
Response: 8111000000000000000000 (Configuration success)
8111010000000000000000 (Configuration failure)
(2) Read Configuration:
Downlink: 0211000000000000000000
Response: 8211003C003C0100000000 (Current configuration)

5.3 Example for MinTime/MaxTime logic

Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
Max Time
S
leeping (Min Time)
1H
Wakes up and
collects data
Note:
REPORTS 2.8V
MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BatteryVoltageChange value.
Device
Type
MinTime
(2bytes Unit: s)
(0x00_success)
0x11
MinTime
(2bytes Unit: s)
003C(H
2H
Wakes up and
collects data
REPORTS 2.8V
NetvoxPayLoadData
MaxTime
(2bytes Unit: s)
Status
Reserved
(9Bytes, Fixed 0x00)
MaxTime
(2bytes Unit: s)
= 60(D
ex)
ec)
Max Time
S
leeping (Min Time)
Wake up and
collects data
REPORTS 2.8V
7
BatteryChange
(1byte Unit: 0.1v)
(4Bytes, Fixed 0x00)
Reserved
(8Bytes, Fixed 0x00)
BatteryChange
(1byte Unit: 0.1v)
(4Bytes, Fixed 0x00)
3H
Reserved
Reserved