5.3 Geomagnetic Threshold Configuration

Fport: 0x07
(It is not recommended to modify the default settings of the device to prevent incorrect setting, which will cause false
detection of parking status)
Description
Device
SetDetect
ThresholdReq
SetDetect
ThresholdRsp
R719A
GetDetect
ThresholdReq
GetDetect
ThresholdRsp
(1) Configure the device geomagnetic threshold parameter to 50 (default is 40)
Downlink: 0359003200000000000000
The device returns:
(2) Read device parameters
Downlink: 0459000000000000000000
The device returns:
8459003200000000000000 (current device configuration parameters)

5.4 Example for MinTime/MaxTime logic

Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
MaxTime
Sleeping(MinTime)
Wakes up and collect data
REPORTS 3.6V
Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BatteryVoltageChange
value.
Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
Cmd
Device
ID
Type
0x03
0x83
0x59
0x04
0x84
8359000000000000000000 (configuration successful)
8359010000000000000000 (configuration failed)
Wakes up and collect data
REPORTS 3.6V
NetvoxPayLoadData
DetectThreshold(2bytes)
Status(0x00_success)
Reserved (9Bytes,Fixed 0x00)
DetectThreshold(2bytes)
MaxTime
Sleeping(MinTime)
Wake up and collect data
8
Description
Reserved (7Bytes,Fixed 0x00)
Reserved (8Bytes,Fixed 0x00)
Reserved (7Bytes,Fixed 0x00)
REPORTS 3.6V