  • Page 1 MIEN2204 Series Unmanaged Industrial Ethernet Switch User Manual Edition: V2.0) Wuhan Maiwe Communication Co., Ltd.
  • Page 2 Copyright Copyright © Wuhan Maiwe Communication Co., Ltd. Clarification The user manual is applicable to MIEN2204 series of industrial unmanaged ethernet switch. Please read the following license agreement carefully before using this manual. The products described in this manual can be used only if you agree on the following license agreement.
  • Page 3 MIEN2204 Series Unmanaged Industrial Ethernet Switch Safe Use Instruction This product performance is excellent and reliable in the designed range of use, but it’s necessary to avoid man-made damage or destroy for the equipment. Read the manual carefully and keep this manual for reference if need afterwards.
  • Page 4: Table Of Contents

    MIEN2204 Series Unmanaged Industrial Ethernet Switch Catalogue 1. Product Overview............- 1 - 1.1. Product Introduction..............- 1 - 1.2. Features..................- 1 - 1.2.1. High-performance Ethernet Switch Interface......... - 1 - 1.2.2. Industrial Power Supply Design............- 1 - 1.2.3.
  • Page 5: Product Overview

    MIEN2204 Series Unmanaged Industrial Ethernet Switch 1. Product Overview 1.1. Product Introduction The MIEN2204 series products produced by Maiwe are high-performance industrial Ethernet switches. The products provide industrial din-rail installation methods, which can adapt to various harsh working environments and have stable communication performance.
  • Page 6: Packing List

    The package of MIEN2204 series products contains the following items. If any of the following items are lost or destroyed, please contact the agent or the customer service center of Maiwe, who will assist you in replacing or making Packing list...
  • Page 7: Interface

    MIEN2204 Series Unmanaged Industrial Ethernet Switch 2. Interface 1 Ground screw 2 Power input interface 3 LED indicator 4 Ethernet Rj45 port 5 10/100M optical fiber interface 6 DIN-Rail deck 2.1. Ground Screw The industrial Ethernet switch has a grounding screw. After crimping one end of the grounding wire with the cold-pressed terminal, the grounding screw is used to fix it at the grounding hole of the chassis.
  • Page 8: Led Indicator

    MIEN2204 Series Unmanaged Industrial Ethernet Switch prevent electric shock. Important hint: Power-on operation: first connect the power cord to the power terminal of the device according to the definition shown in the figure above, and then power on; Power-off operation: first unplug the power plug, then remove the power cord Please pay attention to the sequence of operations above.
  • Page 9: Ethernet Rj45 Port

    MIEN2204 Series Unmanaged Industrial Ethernet Switch Fiber port status LED The port has established a valid network connection LINK 3/4 Blinking Network activity on the port No valid network connection Ethernet RJ45 port status LED Each Ethernet RJ45 port has two indicators. The yellow indicator is the port rate indicator and the green indicator is the port connection status indicator.
  • Page 10: 10/100M Optical Fiber Interface

    MIEN2204 Series Unmanaged Industrial Ethernet Switch 2.5. 10/100M Optical Fiber Interface The 100M optical port of this product is a 100Base-FX full-duplex single-mode or multi-mode optical fiber interface, and the connector can be SC, ST or FC. The optical fiber interfaces need to be used in pairs (TX and RX are a pair).
  • Page 11: Hardware Installation

    MIEN2204 Series Unmanaged Industrial Ethernet Switch 3. Hardware Installation 3.1. Installation Requirements This industrial Ethernet switch is a single structure. Before installation, you must first confirm that there is a suitable working environment, including power requirements, sufficient space, whether it is close to other network equipment to be connected, and whether other equipment is in place.
  • Page 12: Installation

    DIN rail. When you remove the device from the packing box, the DIN rail connection seat should be fixed on the rear panel of the MIEN2204 series switch. If MIEN2204 series switches need to be mounted on DIN rail, you should check the installation of DIN rail before installation.
  • Page 13: Fiber Interface Connecting

    Connecting Power MIEN2204 series switches use power according to the instructions on the product label. When all other cables are connected, the power can be connected 3.3.
  • Page 14 MIEN2204 Series Unmanaged Industrial Ethernet Switch The specifications, quantity, routing direction, and location of the cables to be laid should meet the design requirements of the construction drawing. The wiring length of each cable should be determined according to the actual location.The user cables and power cables should be laid separately.
  • Page 15 MIEN2204 Series Unmanaged Industrial Ethernet Switch Appendix Technical Index IEEE802.3(Ethernet), Protocol Standard IEEE802.3u(100Base-TX&100Base-FX), IEEE802.3x(Flow control) Connector: 1×9 fixed optical port(single/multi-mode optional, SC/FC/ST interface) or RJ45 100M FX port Interface Baud rate:100Base-FX(Optical port),10/100M-TX auto-negotiation Terminal block for power 5.08mm terminal block...
  • Page 16 MIEN2204 Series Unmanaged Industrial Ethernet Switch Dimension Product Selection 100M Fiber 100M (SC/ST/FC) Standard Voltage rj45 port(SC/ST/FC) models rage port Single Single Muti mode mode fiber mode MIEN2204 1. DC power supply: MIEN2204 DC12 ~ -2TS 48V, DC48V (36 ~ 72V).
  • Page 17 WUHAN MAIWE COMMUNICATION CO.,LTD Add.:Building 2, Area E, Phase ii, Optical valley core center, No.52, Liufang road, East Lake Hi-tech Development Zone,Wuhan,China Phone: 027-87170215/16 Fax: +86-027-87170217 www.maiwe.com...