Proportional pressure regulation

Advertisement

Quick Links

Motion Terminal
VTEM
Description
Motion App #03
Proportional pressure
regulation
8071801
2017-12
[8071803]

Advertisement

Table of Contents
loading

Summary of Contents for Festo VTEM

  • Page 1 Motion Terminal VTEM Description Motion App #03 Proportional pressure regulation 8071801 2017-12 [8071803]...
  • Page 2 VTEM Translation of the original instructions VTEM-MA03-EN ® Firefox is a registered trademark of its respective trademark holder in certain countries. Festo – VTEM-MA03-EN – 2017-12 –...
  • Page 3: Table Of Contents

    ................Festo – VTEM-MA03-EN – 2017-12 – English...
  • Page 4: About This Document

    Motion Terminal. Note There may be an updated version of this document for these or later product versions. • Check whether a corresponding version of this document is available (è www.festo.com/sp). Festo – VTEM-MA03-EN – 2017-12 – English...
  • Page 5: Function

    For operating the Motion App on one valve, the ID of the Motion App has to be transferred via the range “operating mode of the valve (valve mode)” of the process data (Bits 5 … 0 in Byte 0 (PDO)) (è Description Motion Terminal VTEM, Function and Parameterisation). Functional description The pressure on the supply air ports (2) and (4) can be regulated individually and independently for each port.
  • Page 6: Diagnostic Messages And Error Elimination

    Characteristics “C2” Characteristics “C3” Tab. 2.3 Defaults The structure of the process data is described in “Function and Parameterisation Motion Terminal VTEM”. 2.6.1 Setting of the Motion App (app option) Is not used. Festo – VTEM-MA03-EN – 2017-12 – English...
  • Page 7: Control Of The Motion App (App Control)

    The status of the inputs of the digital input module CTMM-…-D-…, that are assigned to the currently used valve (è Description Motion Terminal VTEM, Function and Parameterisation), is shown via the Bits 2 and 0 in Byte 1 (PDI). This status information is only available if proximity sensors are installed in the end positions of the drive.
  • Page 8: Actual Values 1 And 2 (Actual Value 1, Actual Value 2)

    –1000 … +32767 × 1 mbar 16 Bit Signed Integer 3 … 2 –1000 … +32767 mbar 1 mbar –1000 … +32767 × 1 mbar 16 Bit Signed Integer 5 … 4 Tab. 2.8 Festo – VTEM-MA03-EN – 2017-12 – English...
  • Page 9: A Technical Appendix

    Zero point suppression [mbar] (The controller is activated not before the setpoint value is larger by this value than the internally measured exhaust pressure. Otherwise the port is exhausted.) Tab. A.1 Festo – VTEM-MA03-EN – 2017-12 – English...
  • Page 11 Copyright: Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany Phone: +49 711 347-0 Fax: +49 711 347-2144 e-mail: Reproduction, distribution or sale of this document or communication of service_international@festo.com its contents to others without express authorization is prohibited. Offend­...