TRIGGER GUN:

1. Be certain the trigger gun is locked in the "OFF" position. See WARNING ,
right.
2. The nozzle assembly should be disconnected from the gun assembly at this
time by unscrewing the nozzle/lance assembly from the gun/lance assembly.
DIRECTION "A"=CONNECTION / "B"=DIS-CONNECTION

WATER SUPPLY:

1. Select a water supply hose which is a quality grade of garden hose
measuring at least 3/4" ID and no longer than 50 feet.
2
Check the water inlet strainer (2) to ensure it is clean and free of any
obstructions. Periodic cleaning of the water strainer will help prevent pump
problems. As a strainer becomes obstructed, it restricts proper flow of
water to the pump. This can result in cavitations which will cause premature
failure of pump packings. Using a screw driver, remove the screen and clean
or replace. Using a screwdriver, remove the strainer from the unit. Clean or
replace with Nilfisk-Advance #56632999 if necessary.
3. Connect the hoses:
a. Connect one end of the water supply hose to the water inlet (1) of the
unit.
b. Connect the other end of the hose to your pressurized water supply.
NOTE: Do not use a non-pressurized water supply (i.e. well or pond water) with
this unit.
c. Screw-connect the high pressure discharge hose (13) to the water
outlet of the unit.
4. Follow the incoming water requirements listed below:
a. Water pressure must be a minimum of 20 pounds per square
inch (PSI) and a maximum of 125 PSI. (A typical outdoor faucet
will generally supply this PSI if turned completely "ON")
b. Incoming GPM must be approximately one gallon more than the
outgoing GPM stated on the pressure washer nameplate. (You
can check GPM by timing how long it takes to fill a 5 gallon
container)
c. Incoming water temperature must not exceed 70°F/21°C.
Excessive pump damage may result if the water temperature
exceeds this acceptable level.
5. Never allow the unit to operate without the incoming water line attached and
the water supply turned all the way on.
6. Protect from freezing. Do not run for more than 3 minutes with spray gun
not triggered.