DM240-DVB High-Speed Digital Modulator
radPcrRestamping OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Enables the PCR restamping in AASI."
::= { radSNMP_Mod_NV_Status 37 }
radMultiPiicMode OBJECT-TYPE
SYNTAX INTEGER {
manual(1),
redundancy(2)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the Multi-PIIC mode."
::= { radSNMP_Mod_NV_Status 38 }
radRedundancyMode OBJECT-TYPE
SYNTAX INTEGER {
force_prime(0),
force_backup(1),
manual_revert(2),
auto_revert(3)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the Redundancy submode if the Multi-PIIC mode
is redundancy."
::= { radSNMP_Mod_NV_Status 39 }
radPrimePiicSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"If the Multi-PIIC mode is manual, radPrimePiicSlot
selects the input slot.
If the Multi-PIIC mode is redundancy, radPrimePiicSlot
selects the prime input slot."
::= { radSNMP_Mod_NV_Status 40 }
radBackupPiicSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
"If the Multi-PIIC mode is redundancy, radBackupPiicSlot
selects the backup input slot."
::= { radSNMP_Mod_NV_Status 41 }
-- radRadioFrequencyHz OBJECT-TYPE
--
SYNTAX RadRadioFreqHz (SIZE (8))
--
ACCESS read-write
--
STATUS current
--
DESCRIPTION
--
"Selects RF frequency in Hz."
--
::= { radSNMP_Mod_NV_Status 42 }
--
-- radLoFrequencyHz OBJECT-TYPE
--
SYNTAX RadRadioFreqHz (SIZE (8))
--
ACCESS read-write
--
STATUS current
--
DESCRIPTION
--
"Selects LO frequency in Hz."
TM083 – Rev. 3.0