Radyne ComStream DM240-DVB Installation And Operation Manual page 92

High-speed digital modulator
Table of Contents

Advertisement

Appendix B
}
RadRadioFreqHz ::= TEXTUAL-CONVENTION
DISPLAY-HINT
"d"
STATUS
current
DESCRIPTION
"Radio Frequency in Hz."
SYNTAX
OCTET STRING
radCarrierControl OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Turns carrier on and off"
::= { radSNMP_Mod_NV_Status 1 }
radTransmitPower OBJECT-TYPE
SYNTAX RadPowerLevel (-300..50)
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the Tx power level in tenths of dBm
from +5.0 to -20.0 (70/140 MHz),
from -5.0 to -30.0 (L-Band).
There is an implied decimal point. For example, a value
of 39 represents a transmit power level of +3.9 dBm."
::= { radSNMP_Mod_NV_Status 2 }
radIFFrequency OBJECT-TYPE
SYNTAX INTEGER (50000000..1750000000)
ACCESS read-write
STATUS current
DESCRIPTION
"Selects IF frequency in Hz."
::= { radSNMP_Mod_NV_Status 3 }
radDataRate OBJECT-TYPE
SYNTAX INTEGER (0..238000000)
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the data rate in bps. Note: Changing data rate
will affect symbol rate, see comment at the end of
mibtext."
::= { radSNMP_Mod_NV_Status 4 }
radSymbolRate OBJECT-TYPE
SYNTAX INTEGER (0..68000000)
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the symbol rate in sps."
::= { radSNMP_Mod_NV_Status 5 }
radSymbolRateMode OBJECT-TYPE
SYNTAX INTEGER {
variable(0),
fixed(1)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Selects symbol rate mode. This can only be modified if
the factory configuration is set to both variable and
fixed.
This is obsolete."
B-2
DM240-DVB High-Speed Digital Modulator
TM083 – Rev. 3.0

Advertisement

Table of Contents
loading

Table of Contents