DM240-DVB High-Speed Digital Modulator
::= { radSNMP_Mod_NV_Status 14 }
radClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
inverted(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects clock polarity for Tx terrestrial clock
relative to Tx data."
::= { radSNMP_Mod_NV_Status 15 }
radDataPolarity OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
inverted(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects data polarity"
::= { radSNMP_Mod_NV_Status 16}
radSpectrum OBJECT-TYPE
SYNTAX INTEGER {
inverted(0),
normal(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Inverts the symbol mapping direction of rotation."
::= { radSNMP_Mod_NV_Status 17 }
radModulationType OBJECT-TYPE
SYNTAX INTEGER {
qpsk(0),
bpsk(1),
psk8(2),
qam16(3)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the modulation type.
Note: Changing modulation type will affect the symbol
rate and data rate. See note at the end of this section."
::= { radSNMP_Mod_NV_Status 18}
radFraming OBJECT-TYPE
SYNTAX INTEGER {
dvb(0)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Selects framing type.
Reserved"
::= { radSNMP_Mod_NV_Status 19 }
radReedsolomon OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
TM083 – Rev. 3.0