Radyne ComStream DM240-DVB Installation And Operation Manual page 100

High-speed digital modulator
Table of Contents

Advertisement

Appendix B
--
::= { radSNMP_Mod_NV_Status 43 }
radRadioFrequencyHz OBJECT-TYPE
SYNTAX Counter64
ACCESS read-write
STATUS current
DESCRIPTION
"Selects RF frequency in Hz."
::= { radSNMP_Mod_NV_Status 42 }
radLoFrequencyHz OBJECT-TYPE
SYNTAX Counter64
ACCESS read-write
STATUS current
DESCRIPTION
"Selects LO frequency in Hz."
::= { radSNMP_Mod_NV_Status 43 }
radLowSideMix OBJECT-TYPE
SYNTAX INTEGER {
high_side(0),
low_side(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the high-side/low-side LO mix."
::= { radSNMP_Mod_NV_Status 44 }
radLocalIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the local IP address."
::= { radSNMP_Mod_NV_Status 45 }
radPilotSymbolsEnabled OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Enables/disables pilot symbols at the physical layer."
::= { radSNMP_Mod_NV_Status 46 }
radPhysLayerScramblerBypass OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
bypassed(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Enables/disables the physical layer scrambler. The
modulator is considered in a test mode when the
scrambler is bypassed."
::= { radSNMP_Mod_NV_Status 47 }
radInnerFecBypass OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
bypassed(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Enables/disables the inner forward error correction.
B-10
DM240-DVB High-Speed Digital Modulator
TM083 – Rev. 3.0

Advertisement