Changing Group Of Parameters - Besam SW200i Installation And Service Manual

Swing door operator (ohc)
Hide thumbs Also See for SW200i:
Table of Contents

Advertisement

14 Changing group of parameters

14
Changing group of parameters
a Disconnect the electrical power contact.
b Press the LEARN BUTTON (LRN) and keep it depressed.
c Connect the electrical power contact.
d Watch the ERROR LED.
3 s
e Release the LEARN BUTTON after the 5 seconds (LED is out).
The ERROR LED flashes a number of short flashes that corresponds to the parameter group
number (see table). After a short pause the LED will repeat the group number, and so on.
f
Pushing the LEARN BUTTON once, increases the parameter group number. When the highest
parameter group number is reached it will start with number 1 (default) again.
g Push the button until you get the requested parameter group.
h Disconnect the electrical power contact.
i
Next time the electrical power is connected, the operator will use the new group of parameters.
66
1 s
5 s
Issue 2013-02-10
1009937-EI-1.0

Advertisement