F6 Exit Function; F7 Internal Value Display Mode; F8 Weight Hold Mode Setting - Excell X Series User Manual

Weighing scale
Hide thumbs Also See for X Series:
Table of Contents

Advertisement

EXCELL PRECISION CO., LTD.
or
r n p 10
Transmission (Brazil)
Print after removing goods (5%
r n p 11
mode)
Print after removing goods (OK
r n p 12
mode)
Continuous transmission,
r n p 13
bluetooth format
Stable transmission, only weight
r n p 14
value is transmitted

3-3 F6 Exit Function

Use
or
setting.

3-4 F7 Internal Value Display Mode

Use
or
again will see F7.

3-5 F8 Weight Hold Mode Setting

Use
key or
Press
key
Press
Press
Press
key
02036XXX
key
to select F6. Then press
to select F7. Then press
key choose F8
key
Press
key
Press
RS232 transmit
After placing item and become stable, beep twice. RS232
transmit item weight after item is removed.
RS232 transmit only "OK" item weight after item is removed.
No transmission while in "HI" or "LO".
Bluetooth transmit continuously through RS232. Keypad has
no effect.
After return to zero, transmit next stable weight's weight
value only.
to count down to zero and exit the
to display internal value. Press
 Before setup, please switch the SWA1 on
MINI JUMPER to ADJ position
 After setup, please switch the SWA1 on
MINI JUMPER back to LOCK position
In hold mode, press
hold value as shown on display.
(It's not related to the settings of F5
transmission mode, but it needs to select the
key
proper Baud rate according to the
transmission of the receiver.)
(To setup transmission rate, please refer to
F5 RS-232 Interface Output Setting (option))
key
Use
hold 0 ~ hold 4 and then press
complete setup.
18
Print TOTAL and
RS232 transmit
clears totalized
values
key to select a value from
ZSME300000422
key, to print the
key to

Advertisement

Table of Contents
loading

This manual is also suitable for:

TxwFxwSxwAxw