1-4 Power Description

Power consumption varies depending
0~100% backlight used (mA)
Scale has a built-in power saving function to extend usage time. Table below shows the battery
capacity and estimated usage time. Time may vary with different brands of lithium batteries and
are for reference only.
Battery capacity
Average usage time
Estimated charging time
Assume 25% in use for average usage time. If use continuously, time will be reduced by ~40%.
Low Power Alarm
When
symbol flashes, scale needs to be charged. To check the battery level, please
unplug the AC cable first, and check the battery symbol
the display. The number of bars under the battery symbol indicates battery level. 4 bars mean
100%, 3 bars mean 75%, 2 bars mean 50%, 1 bar means 25%, and 0 bar means <= 10% when
the low power warning symbol (
charge immediately, scale auto shuts down within 5~10 hours or 1~2 hours with backlight. The
cut voltage is about 3.5V. Once it auto shuts down and enters the battery protection mode, it
must be charged before it can be used again.
Please recharge at once when the symbol

1-5 Error Messages

oL  Weight exceeds 9d of maximum capacity. (d=division)
E1  Zero value after power on is over +10% FS.
E2  Zero value after power on is less than -10% FS.
need to set C5 to 1 to have E1 and E2 warnings
E4  Unstable zero return, unstable over 10 sec. Press
E6  Zero is too high when calibrating. (over internal value 350,000)
E7  Zero is too low when calibrating. (under internal value 80,000)
E8  Resolution is set higher than factory setting. Send it back to us to unlock to set new
resolution.
E10  The scale is not in level status.(only available with level detector equipment.)
- - - - - -  For weight < -20d without tare or pretare device in operation.
OIML approval models need to set C5 to 1 to show "- - - - - -"
E10 Level Switch (option)
Make PCB J3 open circuit and connect signal to CN7 of PCB. Display shows E10 after 2
seconds and all keys stop working in the mean time. If you do not need level switch, make
J3 short circuit.
02036XXX
Power
2000mA
2500mA
80~90
95~105
hours
hours
≈2.5 hours
≈3 hours
) flashes to indicate that scale needs to be charged. If not
Battery
18650 3.7V lithium battery
Plugged in
No backlight
75% backlight (factory default)
≈ 24
3000mA
110~120
hours
≈3.5 hours
displayed in the lower left corner of
shows in order to keep the weight accuracy.
to leave E4.
6
100~240V AC
≈ 28
3200mA
3500mA
120~130
130~140
hours
hours
≈4 hours
≈4.5 hours
ZSME300000422