4) The load placed on the weigh pan must not exceed the maximum weighing capacity of the scale. 5) If the scale is not going to be used for some time, please clean it and store it in a plastic bag in dry conditions. A desiccant sachet may be included to prevent moisture build up.
..PERFORMANCE: High Precision Counting Scale (1/15,000 and 1/ 30,000 Display Resolution) Minimum Sampling Weight = at least 20d. Minimum Unit Weight = at least 0.2d Standard Counting Scale (1/6,000 Display Resolution) Minimum Sampling Weight = at least 40d. Minimum Unit Weight = at least 0.8d...
EXCELL PRECISION CO., LTD 1-2 KEYBOARD FUNCTION STANDARD TYPE ADDITIONAL FUNCTIONS TYPE I SMPL Counting Q’TY SMPL This is a “CLEAR” key to delete all the High UNIT Limit values. Please W.T. refer to page 21. Dual Weighing Unit Q’TY This Key is to select weight units of “lb”or...
Page 9
EXCELL PRECISION CO., LTD ADDITIONAL FUNCTIONS TYPE II Counting Unit Weight Preset Q’TY SMPL This key selects 10 pre-set stores of piece weight. UNIT U.W. Please refer to page 24. W.T. This key selects 10 pre-set ..
Page 10
EXCELL PRECISION CO., LTD COMBINATION TYPE Weight Stores Counting Dual Weighing Units + Preset Piece Q’TY SMPL This is a dual function key UNIT U.W. which selects: W.T. Preset piece weight stores and weighing units selection. Please refer to page 27.
CHAPTER 2 OPERATION 2-1 SWITCH SCALE ON To switch on the scale, ensure that the weigh pan is empty and press the ON/OFF ”) position and the scale will power on and set zero ready for switch towards the (“...
& other unstable environments a useful additional facility is available. With the zero display mask it is possible to configure the scale not to show the first division of the weight. When configured the weight display will show zero as long as the weight is less than two display divisions.
Enter the weight value to be used and then place the weight on the scale, when the reading is stable the scale will automatically calibrate. While the scale is counting back to zero, remove all the weights from the scale. The Calibration procedure is finished. The new calibration will be stored and recalled when the scale is switched off and on again.
2.8g, then because the difference between the to unit weights is greater than 10% the scale will average the two values and set a new unit weight of 2.65g. If the difference in unit weights are less than 10% then the unit weight is not re-calculated.
Ž When the quantity display is flashing, press the Sampling Weight • Once the scale stabilizes, the count is shown on the quantity display. Sampling Weight 2-8-2 The Unit Weight of Object is Known Œ Enter the known weight of the item...
Œ Place the container onto the scale. Container Weight • Press T Key. Ž Once the scale stabilizes, it will display the net weight and the “3” icon next to the NET symbol will be displayed. 2-9-2 Clear Tare Value When the container is removed from the scale, the weight display will show a negative sign.
2-9-3 The Weight Container is Known (Pre-set Tare) The User mode function to operate the “Pre-set tare” is to set “0” not perform a pre-set tare when there is a weight on the scale. Œ Nothing is placed on the scale.
EXCELL PRECISION CO., LTD 2-9-4 Clear The Pretare Value When the container is removed from the scale, the weight display will show a negative sign. Press the T key to clear pre-tare value and the weight display will reset to zero, the “3” icon adjacent to the NET symbol will go off.
Œ Place a desired object onto the scale Object Weight • Press M+ Key Ž Once the scale is stable. Total Weight Totalised • After 3 seconds, the scale will return to the counting mode. Object Weight Counting Unit Weight Object Q’ty Placed on Scale...
With both the weight and the unit weight displaying zero, press totalised value. Total Weight Totalised 2-10-3 Weight Totalising Œ With the unit weight display showing zero, place an object onto the scale. Object Weight • Press M+ key. Ž Once the scale has stabilized.
Press the MC key to clear all of the totalised values and the “3” symbol adjacent to the M+ icon on the overlay will switch off. The totals for weight, number of additions and quantity are all cleared back to zero. NOTE: All totals will be lost if the scale is switched off. Counting ZSME200000003...
Press to select the required mode Pre-set Tare function is not available when there is an object on the scale. Pre-set Tare function is available when there is an object on the scale. To exit and save the entry, press the Counting twice.
Press to select the required mode 0 = The quantity will be accepted by the scale only when the weight is stable. 1 = The quantity will be accepted by the scale even if the weight is un-stable. To exit and save the entry, press the...
Weight Press to select the required mode 0 = After M+ operation, next M+ operation is allowed only after the scale Returns to Zero. 1 = After M+ operation, next M+ operation is allowed immediately, without the scale Returning to Zero.
Page 26
EXCELL PRECISION CO., LTD the scale. Counting ZSME200000003...
EXCELL PRECISION CO., LTD 3-7 BAUD RATE SETTING (for only with the serial interface) Press then Weight Press to select the required baud 0 = 1200 1 = 2400 2 = 4800 3 = 9600 To exit and save the entry, press the...
CHAPTER 4 KEYBOARD TYPES 4-1 STANDARD TYPE 4-1-1 Quantity Preset The scale can store a Hi Limit quantity value. The scale will make a warning beep and the unit weight window will display a blinking over the Hi limit alarm value set.
4-2-2 Quantity Preset The scale can store a Hi Limit quantity value. The scale will make a warning beep and the unit weight window will display a blinking over the Hi limit alarm value set.
EXCELL PRECISION CO., LTD 4-2-3 Weight Preset The scale can store a Hi Limit unit weight value. The scale will make a warning beep and the unit weight window will display a blinking if the unit weight is over the Hi limit value stored.
4-3 TYPE II UNIT WEIGHT PRESET 4-3-1 Unit Weight Preset Stores The scale can store 10 sets of unit weight presets. The stores are accessed using the number keys ( display will show the unit weight previously saved in that store.
EXCELL PRECISION CO., LTD 4-3-2 Quantity Preset The scale can store a Hi Limit quantity value. The scale will make a warning beep and the unit weight window will display a blinking over the Hi limit alarm value set. Hi Limit Value for Quantity Preset Œ...
EXCELL PRECISION CO., LTD 4-3-3 Weight Preset The scale can store a Hi Limit unit weight value. The scale will make a warning beep and the unit weight window will display a blinking if the unit weight is over the Hi limit value stored.
(If the unit selection setting is a secondary function, press the combination key for about 3 seconds and the display will show the following) Remarks : The scale will save the current unit in use. At power on the last units in use will be used. Counting DUAL WEIGHING UNIT + Q’TY...
EXCELL PRECISION CO., LTD 4-4-2 Unit Weight Preset Stores The scale can store 10 sets of unit weight presets. The stores are accessed using the number keys ( display will show the unit weight previously saved in that store. Set Unit Weight Preset Œ...
EXCELL PRECISION CO., LTD 4-4-3 Quantity Preset The scale can store a Hi Limit quantity value. The scale will make a warning beep and the unit weight window will display a blinking over the Hi limit alarm value set. Set the Hi Limit Value for Quantity Preset Œ...
EXCELL PRECISION CO., LTD 4-4-4 Weight Preset The scale can store a Hi Limit unit weight value. The scale will make a warning beep and the unit weight window will display a blinking if the unit weight is over the Hi limit value stored.
Press key and the display window will not show the totalised value as the buzzer will beep. Press the key to exit the setting mode and the scale will return to counting mode. Counting UNIT WEIGHT UNIT WEIGHT UNIT WEIGHT...
Preset tare is not allowed if there is a weight on the scale. Preset tare will operate at any point throughout the weighing range. Press the key to exit the setting mode and the scale will return to counting mode. Counting UNIT WEIGHT...
The “Q’TY PST” will only operate when the weight is stable. The “Q’TY PST” will operate irrespective of the stability of the weight. Press the key to exit the setting mode and the scale will return to counting mode. Counting UNIT WEIGHT...
Totalising will only be carried out when the weight is stable. Totalising will be carried out irrespective of the stability of the weight. Press the key to exit the setting mode and the scale will return to counting mode. Counting UNIT WEIGHT...
The weight needs to return to zero before the next totalising operation is allowed. Allow next totalising operation without return to zero interlock. Press the key to exit the setting mode and the scale will return to counting mode. Counting UNIT WEIGHT UNIT WEIGHT...
Press the “Unit Weight Preset” function key (main function) and hold it down for 3 seconds, the unit selection function becomes the secondary function. Press the key to exit the setting mode and the scale will return to counting mode. Counting UNIT WEIGHT...
WEIGHT Use number keys 0 to 3 key to select Once the setting is done, re-start the scale by turning the power off / on. Press the key to exit the setting mode and the scale will return to counting mode.
Use the number keys 0 to 3 to select Press Stream transmit Once the setting is done, re-start the scale by turning the power off / on. Press the key to exit the setting mode and the scale will return to counting mode.
Page 46
EXCELL PRECISION CO., LTD NO. No. of totalising operations N/W Net Weight U/W Unit Weight PCS Piece T/N Total no. of totalising operations T/W Total Weight T/A Total Amount Counting ZSME200000003...
Need help?
Do you have a question about the Counting Scale and is the answer not in the manual?
Questions and answers