Excell SI-132 User Manual

Excell SI-132 User Manual

Anti-moisture weighing scale
Hide thumbs Also See for SI-132:

Advertisement

Anti-moisture
Weighing Scale
User Manual
© Excell Precision Limited 2016. All rights reserved Worldwide.
The information contained herein is the property of Excell Precision Limited and is
supplied without liability for errors or omissions. No part may be reproduced or used
except as authorized by contract or other written permission. The copyright and the
foregoing restriction on reproduction and use extend to all media in which the
information may be embodied.

Advertisement

Table of Contents
loading

Summary of Contents for Excell SI-132

  • Page 1 User Manual © Excell Precision Limited 2016. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorized by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.
  • Page 3: Table Of Contents

    EXCELL PRECISION CO., LTD. Table of Content Instructions for Use ......................... 2 Preparing to Use the Scale ......................2 Chapter 1 Introduction ........................4 1-1 Display Description ......................4 1-2 Keypad Function ....................... 4 1-3 Operating the Scale ......................5 1-4 Self-Test Mode ........................
  • Page 4: Instructions For Use

    EXCELL PRECISION CO., LTD. Thank you for purchasing our Anti-moisture Weighing Scale. In order to use the scale properly, please read this manual carefully before use. If you have a problem concerning the scale, please contact your supplier. Instructions for Use Please keep the scale clean and away from insect intrusion.
  • Page 5 EXCELL PRECISION CO., LTD. Due to the storage battery adopt the advanced free-maintaining technique, customers need not to replenish electrolyte. The scale should be recharged every 3 months to prevent failure of the internal rechargeable battery. 1. The battery should be charged for 8~10 hours.
  • Page 6: Chapter 1 Introduction

    EXCELL PRECISION CO., LTD. Chapter 1 Introduction 1-1 Display Description Symbol Indication →0← : “Zero” Indication. : “kg” unit NET : “NET” Indication. : “lb” unit. Pcs : Press this key to enter into counting mode. : When the power indication flashing, it means battery should be recharged.
  • Page 7: Operating The Scale

    EXCELL PRECISION CO., LTD. 1-3 Operating the Scale POWER ON When the scale is off, press the ON/ZERO key, the scale will switch on. POWER OFF When the scale is on, press the key, the scale will switch off. ZERO When the weigh pan is empty (free of load) and the display is not showing zero, press key to zero the scale.
  • Page 8: Self-Test Mode

    EXCELL PRECISION CO., LTD.  The weight of a sample should be heavier than the 0.2d (d=division), or the arrow pointing to the icon will be on.  When the are indicated, the scale is still operational but the count may contain errors.
  • Page 9: Power Supply

    EXCELL PRECISION CO., LTD. 1-5 Power Supply Power Supply Selection Model for rechargeable battery: 1. 6V/5Ah rechargeable battery 2. Adaptor: Output DC 10V 1A Model for alkaline batteries: 1. Four D size alkaline batteries (purchase by customers) Stronly suggest using alkaline batteries, please pay attention to not confusing the new and old batteries.
  • Page 10: Chapter 2 Advanced Functions

    EXCELL PRECISION CO., LTD. Chapter 2 Advanced Functions 2-1 Advanced Function Setting Table Below is an overview of the advanced functions. For detailed settings refer to the following sections: DISPLAY LEVEL 1 FUNCTION DISPLAY LEVEL 2 FUNCTIONS Exit the ADVANCED...
  • Page 11: Advanced Function Setting Workflow

    EXCELL PRECISION CO., LTD. 2-2 Advanced Function Setting Workflow In the weighing mode, press the NET/GROSS and ON/ZERO keys at the same time to enter the Advanced Function setting mode. The LCD shows Overall workflow of the Advanced Function setting mode:...
  • Page 12: General Function Setting

    EXCELL PRECISION CO., LTD. 2-3 General Function Setting There are 7 functions in the general function setting mode from Workflow of the General Function setting: DISPLAY NOTE ACTIONS ON/ZERO key  Upward key (from 0 to 9) UNITS key  Downward key (from 9 to 0) Press TARE key TARE key ...
  • Page 13: Automatic Backlight Function Setting

    EXCELL PRECISION CO., LTD. 2-3-1 Automatic Backlight Function Setting Select in the General Function setting mode to change the backlight function setting. DISPLAY NOTE ACTIONS Press TARE key LCD displays the last status Use ON/ZERO or UNITS key to select function “on” or “off Press TARE key Key in the parameter “00”...
  • Page 14: Automatic Power-Off Timer Setting

    EXCELL PRECISION CO., LTD. 2-3-2 Automatic Power-off Timer Setting Select in the General Function setting mode to change the automatic power-off timer setting. DISPLAY NOTE ACTIONS Press TARE key LCD displays the last status Use ON/ZERO or UNITS key Automatic power-off timer setting...
  • Page 15: Hi/Lo/Ok Function Setting

    EXCELL PRECISION CO., LTD. 2-3-3 Hi/Lo/OK Function Setting Select in the General Function setting mode to set the Hi/Lo/OK function. This function is available in all unit modes. In one specific unit mode, enter to set the Hi/Lo/OK values.  When the high limit and low limit are both set as “0”, the Hi/Lo/OK function is disabled.
  • Page 16: Restore To The Default Setting

    EXCELL PRECISION CO., LTD. 2-3-4 Restore to the Default Setting Select in the General Function setting mode to restore to the default setting. DISPLAY NOTE ACTIONS  Return (Cancel the Press TARE key restoration)  Restore to the default Use ON/ZERO or UNITS keys setting to select “return”...
  • Page 17: Noise Filter Setting

    EXCELL PRECISION CO., LTD. 2-3-5 Noise Filter Setting Select in the General Function setting mode to set the noise filter setting.  When modifying , the parameters of remain un-altered. NOTE ACTIONS DISPLAY Returning to zero point setting LCD displays the last status...
  • Page 18: Hold Function Setting

    EXCELL PRECISION CO., LTD. 2-3-6 Hold Function Setting Select in the General Function setting mode to set the hold function. ACTIONS NOTE DISPLAY Press TARE key Hold function setting LCD displays the last parameter setting Hold function setting Use ON/ZERO or UNITS key...
  • Page 19: Auto Unit Weight Averaging Setting

    EXCELL PRECISION CO., LTD. 2-3-7 Auto Unit Weight Averaging Setting Select in the General Function setting mode to set Auto Unit Weight Averaging. ACTIONS NOTE DISPLAY Press TARE key Auto unit weight averaging setting LCD displays the last parameter setting...
  • Page 20: Weight Calibration

    EXCELL PRECISION CO., LTD. 2-4 Weight Calibration In the weighing mode, press the NET/GROSS and ON/ZERO keys at the same time to enter the Advanced Function setting mode. The LCD shows and use the NET/GROSS or UNITS key to select to enter the weight calibration mode.
  • Page 21: Appendix 1 7-Segment Display Characters

    EXCELL PRECISION CO., LTD. Appendix 1 7-Segment Display Characters 7 segments 7 segments 7 segments Digit Alphabet Alphabet letter letter letter 02005318 ZSME300000298...